23. INSPECTION BEFORE EVERY USE
1. Visual check.
2. Lead-in cable check.
3. Condenser cleanliness check (in case of excess pollution of the condenser, clean more fre-
quently than 1x a month).
4. Inspection of water level.
WARNING:
Do not use the device if defects or malfunctions are found.
22. MAINTENANCE
Flush the beverage tubing of the cooler after
each use with pressurised water (see Sanita-
tion by Water). To make flushing easier, use a
sanitation adapter according to your type of
keg coupler (not included in standard accesso-
ries). The cooler must be sanitised once every
14 days by a person with chemical
engineering qualifications. The condenser
must be checked for cleanliness every month.
Any dirt found must be cleaned with com-
pressed air or wiped off. Otherwise, there is a
risk of reduced cooling output or damaging of
the cooler.
25. ENVIRONMENTAL PROTECTION
Waste Sorting
This product must not be disposed of in communal waste. Electrical waste in the Czech
Republic is disposed of within the Rema System (www.remasystem.cz).
In countries other than the Czech Republic, waste sorting is subject to local regulations.
Sorting waste allows recycling and reusing used products and packaging materials. Reuse
of recycled material helps protect the environment from pollution and reduces resource
consumption. Local regulations may regulate the method of disposing of household ap-
pliances at local collection points or at the point of sale.
18. PERIODIC CHECKS:
1x day: check the water level in the tank.
1x a week: check that the lead-in cable is
undamaged and that the plug is firmly in the
socket.
1x a week: check that the device is not ex-
posed to radiant heat.
1x a week: check that air circulation is not
obstructed.
1x a month: check the cooling unit‘s con-
denser and clean it regularly.
1x a month: check water purity in the devi-
ce (chiller tank), or change it if necessary.
1x a year: have an engineering inspector
check the electrical safety of the device.