6.5.
DAMAGES OR BREAKDOWNS RESEARCH AND MOVING ELEMENTS
UNBLOCK
Before to proceed to any intervention or investigation
:
1.
Signal, with a sign, that you are performing the maintenance.
2.
Before to restart the machine, check always that there aren’t personnel that are performing cleaning
and/or maintenance operations.
3.
For the controls and the little electric repairs make intervene exclusively qualified and regularly skilled
professional electricians and/or electrotechnics.
4.
For the mechanical reparations contact absolutely, always, the Authorized Assistance Centre.
5.
Consult always and in every case the Authorized Assistance Centre in the ways showed in the first
pages of the present manual.
Here follow the interventions for the
damages or breakdowns research and moving element unblock
are showed that can
be
performed from maintenance men,
having professionalism, in accordance with what defined in the paragraph 6.1.
TYPE
POTENTIAL
CAUSES
MODALITY AND CHECKS
General black out
Contact the electric energy distributor
Net voltage lacking
Fuses or magneto thermals placed
upstream of the machine feeding line
After having eliminated the causes that have determined
the protection device intervention, restore it. In case of
problem persistency contact an electrician.
Protection device inside the machine
Contact an electrician technician: after having eliminated
the causes that have determined the protection device
intervention, restore it.
In case of fuses intervention,
change them with types of
the same model, calibration and intervention curve.
Functioning
breaking
Cause/s not identifiable
Contact directly the Authorized Assistance Centre
The machine
doesn’t function:
the bowl and the
tool don’t rotate
Feeding voltage lacking.
Sectioning devices placed on “OFF”.
Intervened fuses or not functioning
magneto thermals.
Lacked running button functioning
Thermal intervention due to the
overheating
Check and restore the electric energy.
Turn the sectioning devices in the position “ON”
Make change the intervened fuses, check the magneto
thermal switches condition.
Check the START button efficiency and eventually contact
directly the Authorized Assistance Centre.
Wait the complete cooling before the machine restarting