background image

REPAIR PARTS

INSTALLATION INSTRUCTIONS AND REPAIR PARTS LIST FOR 

L61

MOUNTING

The L61 is designed for wall mounting and requires a flat vertical surface 5" wide and 7" high. If a large number of fixtures are to be 
installed, we suggest removing the support bracket from one fixture for use as a template to locate mounting holes. Four 3/8" bolts 
are required for mounting.

For the most efficient operation, we suggest mounting the fixture so that the light head, in a level position, can be placed into the top 
corner of the lowest trailer utilizing the loading location. It should also be mounted as close to the door or opening edge as is practical. 
For safety, the wall bracket should be mounted high enough to be out of the way of pedestrian and equipment traffic. Do not mount in 
a manner that will allow the wall arm to be trapped under an overhead door as it is closing. The fixture should be mounted where it 
will not be directly exposed to the elements. Recommended mounting height is 78" or higher.

For accessibility, note the location of the switch before mounting.

Install the male plug from the arm assembly into the nearest 
120VAC supply outlet. A rocker-type switch is built into the arm 
to allow the light source to be switched on and off without 
unplugging the unit.

90B Centurian Drive • Markham, Ontario L3R 8C4 Canada • Tel: 905-475-5086 

www.lindequipment.net 

WIRING

Lind Equipment L61

Install fixture according to "Mounting" instructions above.  

Position the fixture with the arm in a straight line. Place one 
hand on the light head and the other hand on the flexible arm. 
(Please reference the Installing and Aiming sheet also included 
in the packaging.)

For optimal performance and durability, the fixture is designed to 
be positioned in one long continuous curve. 
 

 Do not overbend or kink the flexible arm

 

• Do not attempt to lubricate the flexible arm

 

• Do not force sharp bends at either endpoint

 

• Do not fold flexible arm back to rest light head on     

         reinforced arm as this will damage the flexible arm

AIMING

ITEM DESCRIPTION

PART NO.

1

LED ASSEMBLY

L61-P1

2

FLEXIBLE ARM

L61-P2

3

ROCKER SWITCH

L61-P3

4

DRIVER

L61-P4

5

SUPPLY CORD

L61-P5

All wiring should be done by licensed electricians in 

 

accordance with local codes, state codes, as well as NEC 

(National Electric Code) standards. Improper installation or 

use may result in serious injury.

CAUTION