Operating Instructions
Pump ZPU 08 ATEX
810-53711-1
Page 33 / 57
Rev.: 003
31/07/2017
4.15.
Connections / outlets
Pressure line
G ¾“
Relief line
G ¾“
Filling adapter
G ¾“
4.16.
Filling possibilities
via filling adapter
via reservoir lid
4.17.
Rotational direction of the pump
The rotational direction is always clockwise (CW). Observe the
arrow on the reservoir. The rotational direction of the motor is as
needed.
4.18.
Admissible speed of the eccentric shaft
Minimum speed
Maximum speed
10 rpm
85 rpm
When supplying the pump without motor and gear, speeds must be maintained by
selecting a suitable motor and gear.
4.19.
Output
approx. 11.2 dm
3
/h
This information applies for grease of NLGI class 2 at +20 °C and 100 bar
counterpressure. Deviating conditions such as different NLGI class, temperature or
counterpressure may lead to a deviation in the flow rate. This should be taken into
account when designing the lubrication points.
4.20.
Lubricant filter
Filter area:
5.1 cm
2
Grade of filtration:
280 μm
Summary of Contents for ZPU 08
Page 1: ...Operating Instructions Pump ZPU 08 ATEX 810 53711 1 Page 1 57 Rev 003 31 07 2017 ZPU 08 ...
Page 52: ...Operating Instructions Pump ZPU 08 ATEX 810 53711 1 Page 52 57 Rev 003 31 07 2017 ...
Page 53: ...Operating Instructions Pump ZPU 08 ATEX 810 53711 1 Page 53 57 Rev 003 31 07 2017 ...
Page 54: ...Operating Instructions Pump ZPU 08 ATEX 810 53711 1 Page 54 57 Rev 003 31 07 2017 ...
Page 55: ...Operating Instructions Pump ZPU 08 ATEX 810 53711 1 Page 55 57 Rev 003 31 07 2017 ...
Page 56: ...Operating Instructions Pump ZPU 08 ATEX 810 53711 1 Page 56 57 Rev 003 31 07 2017 ...
Page 57: ...Operating Instructions Pump ZPU 08 ATEX 810 53711 1 Page 57 57 Rev 003 31 07 2017 ...