3.
Lubricant
Lubricants are used specifically for certain application purposes. In order to fulfil
their tasks, lubricants must fulfil various requirements to varying extents. The most
important requirements for lubricants are:
Reduction of abrasion and wear
Corrosion protection
Noise minimisation
protection against contamination or penetration of foreign objects
Cooling (primarily with oils)
longevity (physical/ chemical stability)
Compatibility with as large a number of materials as possible
economic and ecological aspects.
3.1.
Selection of lubricants
A suitable lubricant is selected already when designing the machine and forms the
basis for the planning of a centralized lubrication system.
The selection is made by the manufacturer/ operator of the machine, preferably
together with the lubricant supplier based on the requirement profile defined by the
specific application.
Should you have little or no experience with the selection of lubricants for
centralized lubrication systems, please contact SKF. You will avoid possible costly
downtimes through damage to your machine/ system or damage to the centralized
lubrication system.
3.2.
Ageing of lubricants
After a prolonged downtime, the lubricant must be inspected prior to
recommissioning as to whether it is still suitable for use due to chemical or physical
ageing. We recommend that you undertake this inspection already after a machine
downtime of 1 week. If doubts arise as to the suitability of the lubricant, please
replace it prior to re-commissioning and, if necessary, undertake initial lubrication
manually.
Summary of Contents for ZPU 08
Page 1: ...Operating Instructions Pump ZPU 08 ATEX 810 53711 1 Page 1 57 Rev 003 31 07 2017 ZPU 08 ...
Page 52: ...Operating Instructions Pump ZPU 08 ATEX 810 53711 1 Page 52 57 Rev 003 31 07 2017 ...
Page 53: ...Operating Instructions Pump ZPU 08 ATEX 810 53711 1 Page 53 57 Rev 003 31 07 2017 ...
Page 54: ...Operating Instructions Pump ZPU 08 ATEX 810 53711 1 Page 54 57 Rev 003 31 07 2017 ...
Page 55: ...Operating Instructions Pump ZPU 08 ATEX 810 53711 1 Page 55 57 Rev 003 31 07 2017 ...
Page 56: ...Operating Instructions Pump ZPU 08 ATEX 810 53711 1 Page 56 57 Rev 003 31 07 2017 ...
Page 57: ...Operating Instructions Pump ZPU 08 ATEX 810 53711 1 Page 57 57 Rev 003 31 07 2017 ...