20
4.2 Output pressure in dependency of the line length and temperature
Pressure d 20 °C
Pressure diagram
±
0 °C
0
0
1
2
3
4
5
5
10
15
20
25
30
Pressure diagram - 10 °C
0
0
1
2
3
4
5
5
10
15
20
25
30
Pr
es
sur
e
in
bar
Length of lubrication line in meters
Ø 4 mm
Ø 6 mm
Inner
dia
met
er
Inner
dia
met
er
Inner
dia
met
er
Pr
es
sur
e
in
bar
Ø 4 mm
Ø 6 mm
0
0
1
2
3
4
5
5
10
15
20
25
30
Length of lubrication line in meters
Pr
es
sur
e
in
bar
Length of lubrication line in meters
Ø 4 mm
Ø 6 mm
ATTENTION
The pressure values stated in the diagrams are average valu-
es out of measurements with SKF lubrication greases of
NLGI 2. These values are to be understood as reference valu-
es. In addition to the shown context between temperature/
line length/ nominal diameter and the pressure resulting the-
reof, there exists the possibility that in case of low tempera-
tures the output may be reduced due to a deteriorated suc-
tion behaviour of the lubricant. This should be considered
when laying out the system. The maximum supply pressure
of the TLMR of 30 bar must not be exceeded.
EN
4. Technical data
Summary of Contents for SKF TLMR 101
Page 38: ...38 Notices ...