![Lincoln QSL User Manual Download Page 11](http://html1.mh-extra.com/html/lincoln/qsl/qsl_user-manual_1917730011.webp)
Subject to modifications
User Manual
Operating Instructions
4.2EN-18005-C10
Page 11 of 16
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
Operating Method, continuation
6 727b06
67 28b06
672 9b06
Fig. 4
Metering procedure
Fig. 5
Final metering position
Fig. 6
Pressure relief
1 Indicator pin
2.3 Piston
2.4 Spring sleeve
2.5 Metering chamber
2.6 Metering channel
2.1 Compression spring
2.2 Distributing chamber
2.4 Spring sleeve
2.5 Metering chamber
2.6 Metering channel
2.7 Shifting channel
3 Valve
3.1 Valve-sealing lip
P1 Pressure of main line (divider bar)
P2 Outlet to the lube points
P1 Pressure of main line (divider bar)
P2 Outlet to the lube points
P1 Pressure of main line (divider bar)
6 730b06
67 31b06
673 2b06
Fig. 7
Shifting process I
Fig. 8
Shifting process II
Fig. 9
Basic position
2.2 Distributing chamber
2.7 Shifting channel
3 Valve opens shifting channel to distribution
chamber
1 Indicator pin
2.1 Compression spring
2.2 Distributing chamber
2.3 Piston
2.4 Spring sleeve
2.5 Metering chamber
1 Indicator pin retracted again