2
Requirements For Maximum Output
In order to utilize the maximum output capability of
the machine, a branch circuit capable of 25 amps at
120 volts, 60 Hertz is required.
A-2
INSTALLATION
POWER MIG (140, 180 MODELS)
A-2
TECHNICAL SPECIFICATIONS
180 Amp units
(K2668-1 180C)
INPUT – SINGLE PHASE ONLY
RATED OUTPUT
OUTPUT
Standard Voltage/Frequency
Input Current
240 V 50 Hz
I
1 max
20 Amps
I
1 eff
10.7 Amps
Voltage/Duty Cycle
Current
Voltage at Rated Amperes
240 V 25%
131 Amps
20
Welding Current Range
Open Circuit Voltage
Wire Speed Range
30 - 180 Amps
34 V
50 - 500 in/min.
1.3 - 12.7 ( m/min.)
Input Voltage/Frequency Fuse or Breaker Size
1
Input Amps Power Cord
240 V 50 Hz
40 Amp Super Lag
20 15 Amp, 240 V,
Three Pin Plug
RECOMMENDED INPUT CABLE AND FUSE SIZES
Height
Width
Depth
Weight
14.0 in
10.15 in
18.6 in
66 Ibs
357 mm
258 mm
472 mm
30 kg
PHYSICAL DIMENSIONS
1
If connected to a circuit protected by fuses use Time Delay Fuse marked “D”.