A-1
INSTALLATION
POWER MIG (140, 180 MODELS)
A-1
TECHNICAL SPECIFICATIONS
180 Amp units
(K2472-1 180T, K2473-1 180C)
INPUT – SINGLE PHASE ONLY
RATED OUTPUT
OUTPUT
Standard Voltage/Frequency
Input Current
230 V 60 Hz
20 Amps @ rated output
208 V 60 Hz
20 Amps @ rated output
Voltage/Duty Cycle
Current
Voltage at Rated Amperes
230 V 30%
130 Amps
20
208 V 30%
130 Amps
17
Welding Current Range
Open Circuit Voltage
Wire Speed Range
30-180 Amps
34 V
50 - 500 in/min.
(1.3 - 12.7 m/min.)
Input Voltage/Frequency Fuse or Breaker Size
1
Input Amps Power Cord
230 V 60 Hz
40 Amp Super Lag
20 50 Amp, 250 V,
Three Prong Plug
(NEMA Type 6-50P)
RECOMMENDED INPUT CABLE AND FUSE SIZES
Height
Width
Depth
Weight
14.0 in
10.15 in
18.6 in
66 Ibs
357 mm
258 mm
472 mm
30 kg
PHYSICAL DIMENSIONS
1
If connected to a circuit protected by fuses use Time Delay Fuse marked “D”.
140 Amp units
(K2470-1 140T, K2471-1 140C)
INPUT – SINGLE PHASE ONLY
RATED OUTPUT
OUTPUT
Standard Voltage/Frequency
Input Current
120 V / 60 Hz
20 Amps @ rated output
Duty Cycle
Current
Voltage at Rated Amperes
20% Duty Cycle
90 Amps
19.5
Welding Current Range
Open Circuit Voltage
Wire Speed Range
30-140 Amps
33 V
50 - 500 in/min.
(1.3 - 12.7 m/min.)
Input Voltage/Frequency Fuse or Breaker Size
1,2
Input Amps
Power Cord Extension Cord
120 V 60 Hz 20 Amp
20
15 Amp, 125 V, 3 Conductor # 12 AWG
Three Prong Plug (4mm
2
) or Larger
(NEMA Type 5-15P) up to 50 ft.(15.2m)
RECOMMENDED INPUT CABLE AND FUSE SIZES
Height
Width
Depth
Weight
14.0 in
10.15 in
18.6 in
58 Ibs
357 mm
258 mm
472 mm
26.3 kg
PHYSICAL DIMENSIONS
1
If connected to a circuit protected by fuses use Time Delay Fuse marked “D”.