TEST PROCEDURE
1.
Remove input power to the wire feeder.
2.
Using the 5/16" nutdriver, remove the
screws from the left side cover
assembly.
3.
Remove the left side cover assembly.
4.
Apply the correct input power (42 VAC)
and check for the presence of 42 VAC
at the (red) AC terminals of the input
rectifier bridge, shown in Figure F.3.
5.
Carefully check for approximately 56
VDC from the (white) DC+ to the (blue)
DC- terminals of the input rectifier
bridge.
6.
Check for approximately 56 VDC from
plug J1 (+) (1J1) to plug J1 (-) (7J1) on
the control board. If the 56 VDC is
present and any or all of the following
test voltages are not correct, the control
board may be faulty and should be
replaced.
INPUT VOLTAGE TEST
(continued)
FIGURE F.3 – INPUT VOLTAGE TEST POINTS.
(RED)
AC
TERMINALS
(WHITE)
DC+
TERMINAL
(BLUE)
DC-
TERMINAL
INPUT
RECTIFIER
BRIDGE
LN-742 & LN-742H
F-15
TROUBLESHOOTING AND REPAIR
F-15