INVERTEC STT II
A-1
INSTALLATION
A-1
STANDARD VOLTAGE
INPUT CURRENT AT RATED OUTPUT
208/230/460/3/60 HZ
32/30/16
200/220/380/415/440/3/50/60 HZ
33/30/18/17/16
TECHNICAL SPECIFICATIONS –Invertec STT II
INPUT- THREE PHASE ONLY
RATED OUTPUT
RECOMMENDED INPUT WIRE AND FUSE SIZES
I
NPUT VOLTAGE
FUSE(SUPER LAG)
INPUT AMPERE
TYPE 75°C
TYPE 75°C
AND FREQUENCY
OR BREAKER
RATING ON
COPPER
COPPER
SIZE
NAMEPLATE
SUPPLY WIRE
GROUND WIRE
IN CONDUIT
IN CONDUIT
AWG (IEC) SIZES
AWG (IEC) SIZES
208/60
40
32
10 (6 mm2)
10 (6 mm2)
230/60
40
30
10 (6 mm2)
10 (6 mm2)
460/60
30
16
10 (6 mm2)
10 (6 mm2)
200/50/60
40
33
10 (6 mm2)
10 (6 mm2)
220/50/60
40
30
10 (6 mm2)
10 (6 mm2)
380/50/60
30
18
10 (6 mm2)
10 (6 mm2)
415/50/60
30
17
10 (6 mm2)
10 (6 mm2)
440/50/60
30
16
10 (6 mm2)
10 (6 mm2)
HEIGHT
WIDTH
DEPTH
WEIGHT
23.2 in
13.2 in.
24.4 in.
100 lbs.
589 mm
336 mm
620 mm
46 kg
OUTPUT
DUTY CYCLE
AMPS
VOLTS AT RATED AMPS
60% Duty Cycle
225
29
100% Duty Cycle
200
28
CURRENT RANGE
OPEN CIRCUIT VOLTAGE
AUXILIARY POWER
Peak Current
1
0 - 450 Amps
85 VDC Maximum
115
2
VAC @ 4 Amps
Background 0 - 125 Amps
42 VAC @ 4 Amps
1
At low input voltages (below 208 VAC) and input voltages of 380 VAC through 415 VAC there may be a 15% reduction in Peak Current.
2
115 VAC not present on European Models.
PHYSICAL DIMENSIONS