background image

English 

English

6

Technical Specifications

INPUT

Input Power at Rated Output

EMC Class

PC65

5 kW @ 100% Duty Cycle

9 kW @ 35% Duty Cycle

A

Input Voltage

400 V 

 15%

Three Phase

PC105

8 kW @ 100% Duty Cycle
15 kW @ 35% Duty Cycle

A

Frequency

50/60 Hz

RATED OUTPUT AT 40°C

Duty Cycle

(Based on a 10 min. period)

Output Current

Output Voltage

PC65

100%

60%
35%

40 A
50 A
65 A

96 Vdc

100 Vdc
106 Vdc

PC105

100%

60%
35%

60 A
80 A

105 A

104 Vdc
112 Vdc
122 Vdc

OUTPUT RANGE

Cutting Current Range

Maximum Open Circuit Voltage

Pilot Arc Current

PC65

20 ÷ 65 A

PC65

540 Vdc

PC65

20 A

PC105

20 ÷ 105 A

PC105

540 Vdc

PC105

20 A

COMPRESSED AIR or GAS

Required Inlet Pressure

5.0bar ÷ 7.5bar

RECOMMENDED INPUT CABLE AND FUSE SIZES

Fuse (delayed) or Circuit Breaker (“D” characteristic) Size

Input Power Cable

PC65

25 A

PC65

4 Conductor, 2.5 mm

2

PC105

32 A

PC105

4 Conductor, 4 mm

2

PHYSICAL DIMENSIONS

Height

Width

Length

Weight

PC65

385 mm

PC65

215 mm

PC65

586 mm

PC65

19 kg

PC105

500 mm

PC105

275 mm

PC105

711 mm

PC105

32 kg

Operating Temperature

-10°C ÷ +40°C

Storage Temperature

-25°C ÷ +55°C

WEEE

07/06

English

Do not dispose of electrical equipment together with normal waste!
In observance of European Directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE)
and its implementation in accordance with national law, electrical equipment that has reached the end of its
life must be collected separately and returned to an environmentally compatible recycling facility.  As the
owner of the equipment, you should get information on approved collection systems from our local
representative.
By applying this European Directive you will protect the environment and human health!

Spare Parts

12/05

Part List reading instructions

 

Do not use this part list for a machine if its code number is not listed.  Contact the Lincoln Electric Service
Department for any code number not listed.

 

Use the illustration of assembly page and the table below to determine where the part is located for your particular
code machine.

 

Use only the parts marked "X" in the column under the heading number called for in the assembly page (# indicate
a change in this printing).

First, read the Part List reading instructions above, then refer to the "Spare Part" manual supplied with the machine, that
contains a picture-descriptive part number cross-reference.

Electrical Schematic

Refer to the "Spare Part" manual supplied with the machine.

Summary of Contents for INVERTEC PC 105

Page 1: ...IM2002 01 2011 Rev 3 INVERTEC PC 65 PC 105 OPERATOR S MANUAL ENGLISH LINCOLN ELECTRIC ITALIA S r l Via Fratelli Canepa 8 16010 Serrà Riccò GE Italia www lincolnelectric eu ...

Page 2: ...C65 INVERTEC PC105 conforms to the following directives 2006 95 CEE 2004 108 CEE and has been designed in compliance with the following standards EN 60529 EN 60974 1 EN 60974 10 2005 Dario Gatti European Engineering Director Machines LINCOLN ELECTRIC ITALIA S r l Via Fratelli Canepa 8 16010 Serra Riccò GE Italia 12 05 ...

Page 3: ...mediately to the dealer For future reference record in the table below your equipment identification information Model Name Code Serial Number can be found on the machine rating plate Model Name Code Serial number Date Where Purchased ENGLISH INDEX Safety 1 Installation and Operator Instructions 2 Electromagnetic Compatibility EMC 5 Technical Specifications 6 WEEE 6 Spare Parts 6 Electrical Schema...

Page 4: ...ating this equipment CE COMPLIANCE This equipment complies with the European Community Directives ARTIFICIAL OPTICAL RADIATION According with the requirements in 2006 25 EC Directive and EN 12198 Standard the equipment is a category 2 It makes mandatory the adoption of Personal Protective Equipments PPE having filter with a protection degree up to a maximum of 15 as required by EN169 Standard WORK...

Page 5: ... not cover the machine with paper cloth or rags when switched on Dirt and dust that can be drawn into the machine should be kept to a minimum This machine has a protection rating of IP23 Keep it dry when possible and do not place it on wet ground or in puddles Locate the machine away from radio controlled machinery Normal operation may adversely affect the operation of nearby radio controlled mach...

Page 6: ...C 105 only This switch enables disables the Remote Control Connector I Remote Control Connector PC 105 only Connect here the remote control unit Refer to the picture below for the functions related to each pin of the connector front view 1 INPUT 0 5Vdc Output Current Adjustment 2 OUTPUT 12Vdc 1A max Auxiliary Power supply 3 GROUND 4 INPUT Start power source active connecting to GROUND 5 GROUND 6 C...

Page 7: ...rn ON One second after the switching ON a click from the starter relay will be heard the unit is now ready to operate Check through the Gas Test B switch that the primary air N is available The working pressure should be set at 5bar Set the desired current value with the Output Current A knob To start the cutting process just press the torch button making sure you are not aiming the torch air blow...

Page 8: ...the electrical power is provided by the public low voltage supply system There may be potential difficulties in ensuring electromagnetic compatibility in those locations due to conducted as well as radiated disturbances This equipment does not comply with IEC 61000 3 12 If it is connected to a public low voltage system it is responsibility of the installer or user of the equipment to ensure by con...

Page 9: ... electrical equipment together with normal waste In observance of European Directive 2002 96 EC on Waste Electrical and Electronic Equipment WEEE and its implementation in accordance with national law electrical equipment that has reached the end of its life must be collected separately and returned to an environmentally compatible recycling facility As the owner of the equipment you should get in...

Reviews: