background image

English 

English

4

 WARNING

The machine doesn't operate without its safety
protection device (torch protection sleeve) properly
mounted.

 WARNING

Always turn OFF the machine when working on the
torch.

K.  Positive Quick Disconnect:  Positive output

connector for the cutting circuit.  As far the ground
connection, this is to be connected to the work piece
and to a "DINSE" connector on the front of the
power source.

L.  Power Switch:  It turns ON / OFF the input power to

the machine.

M.  Input cable:  Connect it to the mains.

N.  Gas Inlet and Pressure Regulator:  Connect here

the hose carrying the gas to the machine.

The air plasma cutting process uses air as primary
cutting gas and as torch cooling gas.  The air circuit
includes a pressure regulator set at 5bar.

The pilot arc is struck by energizing a first
electrovalve (solenoid valve).  Once the cutting arc
is activated a second electrovalve (solenoid valve)
is energized allowing the primary air the flow.  This
valve lets the air flow only when driven by the
electronic logic devices during the pre-flow, post-
flow and cutting stages, or if the Gas Test switch on
the front panel is turned on.

 WARNING

A clean, dry air or nitrogen must be supplied to the
machine.  A pressure setting above 7,5bar could
damage the torch.  Failure to observe these
precautions could result in excessive operating
temperatures or damage to the torch.

O.  Fan:  Provides machine cooling.  It is switched ON

with the machine and continues to run till the
machine is turned OFF.

The design concept at the basis of these power sources
is to have available a current which remains constant at
the set value, independently from the length of the
plasma arc.

 

Connect the torch [J] and the work cable [K].

 

Turn ON the Power Switch [L] placed on the back of
the machine; the LED [C] on the front panel will turn
ON.  One second after the switching ON a "click"
from the starter relay will be heard; the unit is now
ready to operate.

 

Check through the Gas Test [B] switch that the
primary air [N] is available.  The working pressure
should be set at 5bar.

 

Set the desired current value with the Output
Current [A] knob.

To start the cutting process just press the torch button,
making sure you are not aiming the torch air blow
towards people or foreign objects.  During the cutting
process it is possible to hold the torch away from the
work piece for an extended period of time.

 

Avoid to touch the work piece directly with the torch,
when you do not have the torch with the proper
nozzles.

 

The arc length should not be more than 6-7mm.

Once the cutting process is terminated releasing off the
torch button will cause the plasma arc to be turned off;
the air flow will continue for approximately 30sec. (post-
flow) to allow the cooling down of the torch.

Maintenance

 WARNING

For any maintenance or repair operations it is
recommended to contact the nearest technical service
center or Lincoln Electric.  Maintenance or repairs
performed by unauthorized service centers or personnel
will null and void the manufacturers warranty.

The frequency of the maintenance operations may vary
in accordance with the working environment.  Any
noticeable damage should be reported immediately.

 

Check cables and connections integrity.  Replace, if
necessary.

 

Regularly clean the torch head, check its
consumables and if necessary replace them.  Refer
to the torch instruction manual before changing or
servicing the torch.

 WARNING

Refer to the instructions before changing or
servicing the torch.

 

Keep clean the machine.  Use a soft dry cloth to
clean the enclosing case, especially the airflow inlet
/ outlet louvers.

 WARNING

Do not open this machine and do not introduce anything
into its openings.  Power supply must be disconnected
from the machine before maintenance and service.  After
each repair, perform proper tests to check safety
requirements.

Summary of Contents for INVERTEC PC 105

Page 1: ...IM2002 01 2011 Rev 3 INVERTEC PC 65 PC 105 OPERATOR S MANUAL ENGLISH LINCOLN ELECTRIC ITALIA S r l Via Fratelli Canepa 8 16010 Serrà Riccò GE Italia www lincolnelectric eu ...

Page 2: ...C65 INVERTEC PC105 conforms to the following directives 2006 95 CEE 2004 108 CEE and has been designed in compliance with the following standards EN 60529 EN 60974 1 EN 60974 10 2005 Dario Gatti European Engineering Director Machines LINCOLN ELECTRIC ITALIA S r l Via Fratelli Canepa 8 16010 Serra Riccò GE Italia 12 05 ...

Page 3: ...mediately to the dealer For future reference record in the table below your equipment identification information Model Name Code Serial Number can be found on the machine rating plate Model Name Code Serial number Date Where Purchased ENGLISH INDEX Safety 1 Installation and Operator Instructions 2 Electromagnetic Compatibility EMC 5 Technical Specifications 6 WEEE 6 Spare Parts 6 Electrical Schema...

Page 4: ...ating this equipment CE COMPLIANCE This equipment complies with the European Community Directives ARTIFICIAL OPTICAL RADIATION According with the requirements in 2006 25 EC Directive and EN 12198 Standard the equipment is a category 2 It makes mandatory the adoption of Personal Protective Equipments PPE having filter with a protection degree up to a maximum of 15 as required by EN169 Standard WORK...

Page 5: ... not cover the machine with paper cloth or rags when switched on Dirt and dust that can be drawn into the machine should be kept to a minimum This machine has a protection rating of IP23 Keep it dry when possible and do not place it on wet ground or in puddles Locate the machine away from radio controlled machinery Normal operation may adversely affect the operation of nearby radio controlled mach...

Page 6: ...C 105 only This switch enables disables the Remote Control Connector I Remote Control Connector PC 105 only Connect here the remote control unit Refer to the picture below for the functions related to each pin of the connector front view 1 INPUT 0 5Vdc Output Current Adjustment 2 OUTPUT 12Vdc 1A max Auxiliary Power supply 3 GROUND 4 INPUT Start power source active connecting to GROUND 5 GROUND 6 C...

Page 7: ...rn ON One second after the switching ON a click from the starter relay will be heard the unit is now ready to operate Check through the Gas Test B switch that the primary air N is available The working pressure should be set at 5bar Set the desired current value with the Output Current A knob To start the cutting process just press the torch button making sure you are not aiming the torch air blow...

Page 8: ...the electrical power is provided by the public low voltage supply system There may be potential difficulties in ensuring electromagnetic compatibility in those locations due to conducted as well as radiated disturbances This equipment does not comply with IEC 61000 3 12 If it is connected to a public low voltage system it is responsibility of the installer or user of the equipment to ensure by con...

Page 9: ... electrical equipment together with normal waste In observance of European Directive 2002 96 EC on Waste Electrical and Electronic Equipment WEEE and its implementation in accordance with national law electrical equipment that has reached the end of its life must be collected separately and returned to an environmentally compatible recycling facility As the owner of the equipment you should get in...

Reviews: