Lincoln Dual Technology Finisher 1921 Service Manual Download Page 9

DTF – 1920 Series Service Manual 

9

 

 

Switch, Main Power 

WITH POWER OFF: Check continuity between switch 

terminals. Replace switch as needed. 

 

Control transformer 

Check for supply voltage to the primary of the control 

transformer. If no voltage is present, trace wiring back 

to the oven power relay. If voltage is present, check for 

24 VAC at the transformer secondary. If there is 

primary voltage but no secondary voltage, replace 

control transformer. 

 

Air pressure switch 

Check for 208/240VAC to the air pressure switch. If no 

voltage is present, trace wiring back to main power 

switch. This normally open switch should close when 

the main fan is activated. Refer to the “Removal and 

installation” section for proper adjustment. Replace as 

needed. 

 

Switch, Infrared heater 

Check for 208/240VAC to the Infrared heater switch. If 

no voltage is present, trace wiring back to the air 

pressure switch. WITH POWER OFF: Check continuity 

between switch terminals. Replace switch as needed. 

 

Conveyor motor 

Check for supply voltage to the conveyor motor. If no 

voltage is present, trace wiring back to the primary of 

the control transformer. If voltage is present and the 

motor will not run, check the motor windings for opens 

or shorts. 

WITH POWER OFF: Check the motor windings as 

follows: 

Grey to black - 236 ohms    approx. 

Grey to brown  - 236 ohms    approx. 

 Brown to black - 472 ohms    approx. 

If any of the above fails, replace conveyor motor. 

 

Capacitor, conveyor motor 

Check for shorts or grounds. Replace capacitor as 

needed. 

WARNING: Capacitor has a stored charge, discharge 

before testing. 

 

Switch, conveyor reversing 

Check continuity between switch terminals. Replace 

switch as needed. 

 

Oven control 

If there is supply voltage to the motor, and the motor, 

motor capacitor, and reversing switch check good, 

replace the oven control. 

Conveyor motor runs, but there 

is no speed display 

Oven control 

Check for output voltage from oven control to hall effect 

sensor (sensor is located in conveyor motor). Measure 

voltage at the motor connector, red wire and yellow 

wire. Voltage should be approx. 10VDC. If no voltage is 

present, trace wiring back to oven control. If there is no 

voltage present at the oven control, replace the oven 

control. 

 

Conveyor motor 

If there is voltage supplied to the hall effect sensor, 

check for a frequency output from the hall effect 

sensor. Measure frequency across the yellow and white 

wires at the motor connector. Frequency reading 

should be approx. 25 – 100 Hz. If these readings are 

not achieved, replace conveyor motor. If the readings 

are achieved, proceed.  

 

Oven control 

If the hall effect sensor readings are correct, but there 

is no speed indicated on the display, replace the oven 

control. 

 

 

 

 

 

Summary of Contents for Dual Technology Finisher 1921

Page 1: ...INISHER MODEL 1920 SERIES Lincoln Foodservice Products LLC 1111 North Hadley Road Fort Wayne Indiana 46804 United States of America Phone 800 374 3004 U S Fax 888 790 8193 Int l Fax 260 436 0735 Techn...

Page 2: ...The thermocouple will provide varying millivolts to the oven control The oven control supplies 208 240VAC to the coil of the heater relay at intermittent intervals to maintain the desired temperature...

Page 3: ...DTF 1920 Series Service Manual 3 SCHEMATIC DIAGRAM MODEL 1921 S N 8001207 and Below...

Page 4: ...DTF 1920 Series Service Manual 4 SCHEMATIC DIAGRAM MODEL 1922 S N 8001207 and Below...

Page 5: ...DTF 1920 Series Service Manual 5 SCHEMATIC DIAGRAM MODEL 1921 1922 S N 8001208 and Above...

Page 6: ...for supply voltage to the coil of the main fan relay If no voltage is present trace wiring back to the 30 minute time delay relay If voltage is present check to insure contacts are closing Replace as...

Page 7: ...be sure that the thermocouple is securely connected to the oven control If the thermocouple is connected to the oven control and the control indicates PROBE FAIL disconnect the thermocouple from the...

Page 8: ...OFF To check resistance of the elements remove all leads from the elements and use a digital multimeter The element resistance should be as follows 208V 45 ohms approx 240V 58 ohms approx Replace hea...

Page 9: ...he motor windings as follows Grey to black 236 ohms approx Grey to brown 236 ohms approx Brown to black 472 ohms approx If any of the above fails replace conveyor motor Capacitor conveyor motor Check...

Page 10: ...motor from motor mount 6 Reassemble in reverse order and test for proper operation MAIN FAN REPLACEMENT See MOTOR MAIN FAN above SWITCH ON OFF SWITCH STANDBY REPLACEMENT 1 Shut off power at main break...

Page 11: ...in breaker 2 Remove rear cover 3 Remove wires from appropriate heater relay and mark wires for reassembly 4 Remove mounting screws from heater relay and remove heater relay 5 Reassemble in reverse ord...

Page 12: ...r at main breaker 2 Remove control box top Remove tube from air pressure switch 3 Remove wiring from air pressure switch and conveyor motor capacitor and mark all wiring for reassembly 4 Remove two sc...

Page 13: ...ews and remove heating element 5 Reassemble in reverse order and check system operation HEATING ELEMENT INFRARED REPLACEMENT 1 Shut off power at main breaker 2 Remove conveyor and lower finger assembl...

Page 14: ...w control is installed the control will need to be initialized To initialize the new control press and hold the two center buttons on the front control panel After the oven starts release the buttons...

Page 15: ...DTF 1920 Series Service Manual 15 This page intentionally left blank...

Page 16: ...r right Marked RS E 370445 Front element cover F 370446 Front cover G 370447 Finger cover upper H 370442 Columnating plate upper I 370439 Finger housing upper J 370448 Air wash panel upper K 370449 Ai...

Page 17: ...DTF 1920 Series Service Manual 17...

Page 18: ...pring compression E 369413 Drive key F 369410 Coupling sleeve G 370106 Washer H 350259 Screw I 370458 Heating element Infrared 208VAC 370460 Heating element Infrared 240VAC J 370462 Motor conveyor K 3...

Page 19: ...DTF 1920 Series Service Manual 19...

Page 20: ...nd Above G 370468 Cover heating element H 370471 Cooling fan I 370472 Air switch tube assy J 369427 Transformer control K 370459 Heating element 208VAC 370461 Heating element 240VAC L 369479 Relay Hea...