DTF – 1920 Series Service Manual 

6

 

TROUBLESHOOTING GUIDE 

 

 

 

 

 

1921   

 

208 VAC 

 

60 HZ. 

3 PHASE 

 

 

 

1922   

 

240 VAC 

 

60 HZ. 

3 PHASE 

 

SYMPTOM 

POSSIBLE CAUSE 

EVALUATION 

Oven fan will not run 

Incoming power supply 

Check circuit breakers. Reset if required. Call power 

co. if needed. 

 

Fuses, 10 Amp, motor and 

controls 

Check, replace if necessary. 

 

Fuse holder 

Check, replace if necessary. 

 

 

Hi-limit thermostat,  

Oven cavity        

Terminals are normally closed. If open, reset 

thermostat and retest. If thermostat will not hold for 

maximum oven temperature, and oven is not exceeding 

temperature setting, check for proper location of 

capillary bulb in its spring holder. If the capillary checks 

okay, replace the hi-limit thermostat. 

 

Switch, main power 

Check continuity between switch terminals. Replace 

switch as needed. 

 

30 minute time delay relay 

Check for supply voltage to 30 minute time delay relay 

at terminals #1 and #6. If no voltage is present, trace 

wiring back to main power switch. If there is supply 

voltage at terminals #1 and #6, check for output voltage 

at terminals #2 and #3. If there is incoming voltage but 

no output voltage, and the main power switch is on, 

replace the 30 minute time delay relay. 

 

Relay, main fan 

Check for supply voltage to relay contacts, if no voltage 

is present, trace wiring back to power supply. Check for 

supply voltage to the coil of the main fan relay. If no 

voltage is present, trace wiring back to the 30 minute 

time delay relay. If voltage is present, check to insure 

contacts are closing. Replace as needed. 

 

Transformer, Motor 

(MODEL 1922 ONLY) 

Check for 240 VAC supply to the transformer primary. If 

no voltage is present, trace wiring back to relay. If 

240VAC is present at transformer primary, check for 

208VAC at the transformer secondary. If there is 

primary voltage, but no secondary voltage, replace 

transformer. 

 

Circuit breaker(s), 3A. 

Push and reset circuit breakers. Check for voltage to 

the circuit breaker. If no voltage is present, trace wiring 

back to the main fan relay. If there is voltage present, 

proceed.  Check for continuity through the circuit 

breaker, if the circuit breaker has been reset and there 

is no continuity through the circuit breaker, replace the 

circuit breaker.  

 

Main fan motor 

Check for supply voltage at motor. If no voltage is 

present, trace wiring back to circuit breakers.                 

WITH POWER OFF: Check for opens, shorts or 

grounds. Turn fan blade to check for locked rotor. 

 

Capacitor 

Check for shorts or grounds. 

WARNING: Capacitor has a stored charge, discharge 

before testing. 

Oven will not heat 

Main fan motor 

Check for main fan operation. If it is not operating, refer 

to “Oven fan will not run”. 

 

Air pressure switch 

This normally open switch should close when the main 

fan is activated. Refer to the “Removal and installation” 

section for proper adjustment. Replace as needed. 

Summary of Contents for Dual Technology Finisher 1921

Page 1: ...INISHER MODEL 1920 SERIES Lincoln Foodservice Products LLC 1111 North Hadley Road Fort Wayne Indiana 46804 United States of America Phone 800 374 3004 U S Fax 888 790 8193 Int l Fax 260 436 0735 Techn...

Page 2: ...The thermocouple will provide varying millivolts to the oven control The oven control supplies 208 240VAC to the coil of the heater relay at intermittent intervals to maintain the desired temperature...

Page 3: ...DTF 1920 Series Service Manual 3 SCHEMATIC DIAGRAM MODEL 1921 S N 8001207 and Below...

Page 4: ...DTF 1920 Series Service Manual 4 SCHEMATIC DIAGRAM MODEL 1922 S N 8001207 and Below...

Page 5: ...DTF 1920 Series Service Manual 5 SCHEMATIC DIAGRAM MODEL 1921 1922 S N 8001208 and Above...

Page 6: ...for supply voltage to the coil of the main fan relay If no voltage is present trace wiring back to the 30 minute time delay relay If voltage is present check to insure contacts are closing Replace as...

Page 7: ...be sure that the thermocouple is securely connected to the oven control If the thermocouple is connected to the oven control and the control indicates PROBE FAIL disconnect the thermocouple from the...

Page 8: ...OFF To check resistance of the elements remove all leads from the elements and use a digital multimeter The element resistance should be as follows 208V 45 ohms approx 240V 58 ohms approx Replace hea...

Page 9: ...he motor windings as follows Grey to black 236 ohms approx Grey to brown 236 ohms approx Brown to black 472 ohms approx If any of the above fails replace conveyor motor Capacitor conveyor motor Check...

Page 10: ...motor from motor mount 6 Reassemble in reverse order and test for proper operation MAIN FAN REPLACEMENT See MOTOR MAIN FAN above SWITCH ON OFF SWITCH STANDBY REPLACEMENT 1 Shut off power at main break...

Page 11: ...in breaker 2 Remove rear cover 3 Remove wires from appropriate heater relay and mark wires for reassembly 4 Remove mounting screws from heater relay and remove heater relay 5 Reassemble in reverse ord...

Page 12: ...r at main breaker 2 Remove control box top Remove tube from air pressure switch 3 Remove wiring from air pressure switch and conveyor motor capacitor and mark all wiring for reassembly 4 Remove two sc...

Page 13: ...ews and remove heating element 5 Reassemble in reverse order and check system operation HEATING ELEMENT INFRARED REPLACEMENT 1 Shut off power at main breaker 2 Remove conveyor and lower finger assembl...

Page 14: ...w control is installed the control will need to be initialized To initialize the new control press and hold the two center buttons on the front control panel After the oven starts release the buttons...

Page 15: ...DTF 1920 Series Service Manual 15 This page intentionally left blank...

Page 16: ...r right Marked RS E 370445 Front element cover F 370446 Front cover G 370447 Finger cover upper H 370442 Columnating plate upper I 370439 Finger housing upper J 370448 Air wash panel upper K 370449 Ai...

Page 17: ...DTF 1920 Series Service Manual 17...

Page 18: ...pring compression E 369413 Drive key F 369410 Coupling sleeve G 370106 Washer H 350259 Screw I 370458 Heating element Infrared 208VAC 370460 Heating element Infrared 240VAC J 370462 Motor conveyor K 3...

Page 19: ...DTF 1920 Series Service Manual 19...

Page 20: ...nd Above G 370468 Cover heating element H 370471 Cooling fan I 370472 Air switch tube assy J 369427 Transformer control K 370459 Heating element 208VAC 370461 Heating element 240VAC L 369479 Relay Hea...

Page 21: ...DTF 1920 Series Service Manual 21...

Page 22: ...370478 Crumb pan left C 370440 Frame conveyor D 370479 Belt conveyor E 370480 Bracket conveyor bearing F 370481 Flanged bearing conveyor G 370482 Shaft idler H 369515 Drive sprocket I 369952 Connectin...

Page 23: ...veyor D 370479 Belt conveyor E 370480 Bracket conveyor bearing F 370481 Flanged bearing conveyor G 370482 Shaft idler H 369515 Drive sprocket I 369952 Connecting link conveyor three required J 370483...

Page 24: ...DTF 1920 Series Service Manual 24...

Reviews: