1

TO LUBRICA

TE 

AIR V

AL

VE MECHANISM

Disconnect 

air 

to 

pump, 

remove 

the 

four 

cover 

screws, 

cover 

plate 

and cover gasket.

Remove and disassemble the air valve casting from the pump.

The 

air 

valve 

casting 

should 

be 

cleaned 

or 

flushed 

to 

remove 

any 

chips, or other foreign particles prior to re-assembly

.

Before replacing the toggle assembly

, pack cavity with grease.

U

se

N

LG

I

N

o.

1

(l

ig

ht

gr

ad

e)

w

at

er

re

pe

lle

nt

gr

ea

se

Approximately 1 1/2 ounces.

Replace 

cover 

gasket, 

cover 

and 

screws. 

Tighten 

to 

avoid 

air 

leaks.

Summary of Contents for 83167

Page 1: ...st rise beyond air vent hole to expel entrapped air from lubricant Model No 83167 AIR OPERATED GREASE PUMP Series H RATIO LUBRICANT OUTPUT cu in RESERVOIR AIR LUBRICANT LUBRICANT OPERATING PRESSURE PSI PER CYCLE PER MIN 100PSI CAPACITY INLET OUTLET TYPE OF SYSTEM MINIMUM MAXIMUM RECOM MENDED 40 1 11 12 12 LBS 1 8 NPTF F 3 4 NPTF F SL 1 SL 11 1 850 3 550 2 500 SL 32 SL 33 1 200 3 550 1 500 TYPICAL ...

Page 2: ...tainer 50086 1 Bolt 236833 1 Muffler 13808 1 Adapter 50521 4 Screw 236835 1 Packing Nitrile 14449 1 Tie rod 51039 1 Nut 236868 4 Screw 14491 1 Retainer washer 51099 1 Nut 236869 6 Screw 14720 1 Air cylinder 55138 4 Spring 236870 4 Valve seat bolt 14721 1 Piston 55231 1 Spring 237562 1 Air valve casting 14722 1 Needle 55346 1 Follower spring 239330 1 Viton packing assembly 14723 1 Valve seat 56003 1...

Page 3: ...mble the air valve casting from the pump The air valve casting should be cleaned or flushed to remove any chips or other foreign particles prior to re assembly Before replacing the toggle assembly pack cavity with grease Use NLGI No 1 light grade water repellent grease Approximately 1 1 2 ounces Replace cover gasket cover and screws Tighten to avoid air leaks ...

Page 4: ...PERATION The timer runs constantly when current is on drives a cam which has lobes set for the desired lubrication cycle frequency Refer to Service Manual Section C8 Page 133 Series Lobes engage the micro switch lever arm to activate the switch closing the circuit to open the 3 way solenoid air valve permitting air to operate the pump The pump discharges lubricant through the supply line to the in...