Form 403511

TO LUBRICATE AIR VALVE MECHANISM

A. Disconnect air to pump.
B. Perform pressure relief procedure.
C. Remove four cover screws, cover plate and cover plate

gasket.

D. Remove air valve casting from the pump and disas-

semble.

E. Clean or flush the air valve casting to remove any chips

or other foreign particles.

D. Before replacing toggle assembly, pack cavity with

grease using approximately 1-1/2 ounces of N.L.G.I. No.
1 (light grade) water repellent grease.

F. Replace cover plate gasket, cover plate and cover

screws. Tighten to prevent air leaks.

G. Periodic inspection of parts at least once a year is

advised.

IMPORTANT

Start fasteners by hand to avoid
stripping threads when
reassembling.

© Indicates change

CAUTION: Do not
exceed 15 ft. lbs of
torque.

©

Summary of Contents for 82054

Page 1: ...is equip ment The instructions and warnings con tained in this manual shall be read and understood by the owner operator prior to operating this equipment If an owner operator does not under stand Eng...

Page 2: ...ng a system for a specific requirement This pump can develop 7500 PSI working pressure at 150 PSI maximum incoming air pressure Be sure that all system equipment and accessories are rated to withstand...

Page 3: ...alve Do not allow pump to operate when out of material Pump will accelerate quickly and run too fast resulting in costly damage to the pump If the pump accelerates quickly or is running too fast stop...

Page 4: ...nut 11904 and packing cap 11905 from air valve casting E Remove four valve cover screws 236868 and cover 236286 F Remove four toggle plate screws 236869 toggle assembly 91331 and trip shoe 11475 G Re...

Page 5: ...fasten ers per stated torque specifications IMPORTANT To prevent damage to air piston packing and pump gland packing and to help increase packing life lubricate air cylinder and air piston rod before...

Page 6: ...ip rod packing 236835 and gasket 33039 for cut or damaged packing LOSS OF PRESSURE VOLUME OR CONTINUOUS OPERATION OF PUMP WHEN NOT IN NORMAL USE Remove and clean lower inlet checks Check for foreign m...

Page 7: ...to remove any chips or other foreign particles D Before replacing toggle assembly pack cavity with grease using approximately 1 1 2 ounces of N L G I No 1 light grade water repellent grease F Replace...

Page 8: ...pensing equipment and other related equipment manufactured by it will be free from defects in material and workmanship during the one 1 year following the date of purchase If equip ment proves to be d...

Reviews: