English 16 English
Spot cycle (…)
Pressing the trigger activates wire feed and pre-gas and turns on the welding current. Releasing the trigger causes the
welding to stop.
Adjustment of the Hot Start, down-slope and sequencer settings is disabled. At the end of the spot time-delay, welding
stops.
Sequencer cycle
The sequencer is validated by the parameter “
tSE
0FF
” in the specific cycle submenu of
.
To access it :
The "
tSE
" parameter is displayed in the "
CYCLE
" menu
Set this parameter to a value between 0 and 9.9 s.
TSE
: DURATION OF THE 2 STEPS IF
Off
.
ISE
:
2nd level current a
s % of the 1st level.
AVAILABLE ONLY IN SYNERGIC MODE, 2T CYCLE, OR 4T CYCLE
Fine setting
(parameter adjustable in the "
rFP
cycle setup menu)
In pulsed welding, the fine-setting function enables optimising the place of droplet detachment according to the variation
in the compositions of utilized wires and welding gases.
When fine spatter that may adhere to the workpiece is observed in the arc, the fine-tune setting must be changed toward
negative values.
If large drops are transferred by the arc, the fine-tune setting must be changed towards positive values.