523009
Pressure Relief Valve (PRV) reached maximun allowed opening time count
523350
Injector cylinder-bank 1; short circuit
523352
Injector cylinder-bank 2; short circuit
523354
Injector powerstage output defect
523470
Pressure Relief Valve (PRV) forced to open by pressure increase or pressure shock
Rail pressure out of tolerance range; Maximum rail pressure in limp home mode exceeded (PRV)
523550
T50 start switch active for too long
523601
Sensor supply voltage monitor 3 error (ECU)
523612
ECU reported internal software error; Softwarereset CPU
523613
Rail pressure disrupted; Minimum rail pressure exceeded (RailMeUn3)
Setpoint of metering unit in overrun mode not plausible
523615
Metering unit (Fuel-System); open load or short circuit to either ground or battery
523698
Shut off request from supervisory monitoring function
523776
Timeout Error of CAN-Receive-Frame TSC1TE - active
523777
Passive Timeout Error of CAN-Receive-Frame TSC1TE; Setpoint
523895
Check of missing injector adjustment value programming (IMA) injector 1 (in firing order)
523896
check of missing injector adjustment value programming (IMA) injector 2 (in firing order)
523897
check of missing injector adjustment value programming (IMA) injector 3 (in firing order)
523898
check of missing injector adjustment value programming (IMA) injector 4 (in firing order)
523906
Electrical fuel pre - supply pump; open load; powerstage over temperature or short circuit to either ground
or battery
523982
Powerstage diagnosis disabled; battery voltage either high or low
524057
Electric fuel pump; fuel pressure build up error
524108
Timeout error of CAN-Transmit-Frame ComEGRTVActr
524109
Timeout error of CAN-Receive-Frame ComRxEGRTVActr
SPN
(code)
Error Code Description
E-7
TROUBLESHOOTING
SAE-500
TM
AND SAE-500
TM
SEVERE DUTY
TM