TROUBLESHOOTING & REPAIR
F-45
F-45
RANGER 10-LX
This is the typical CV output voltage
generated from a properly operating
machine. Note that each vertical
division represents 20 volts and that
each horizontal division represents 5
milliseconds in time.
Note: Scope probes connected at
machine output terminals.
SCOPE SETTINGS
Volts/Div.....................20V/Div.
Horizontal Sweep.....5 ms/Div.
Coupling ............................DC
Trigger .........................Internal
NORMAL OPEN CIRCUIT WELD VOLTAGE WAVEFORM (HIGH CV MODE)
HIGH IDLE – NO LOAD – OUTPUT CONTROL AT MAXIMUM
CH1
0 volts
5 ms
20 volts