Lincoln Electric PRO-CUT 40 Operator'S Manual Download Page 2

– 2 –

PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH. KEEP CHILDREN
AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.

Read and understand the following safety highlights. For additional safety information it is strongly recommended that you pur-
chase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box 351040,
Miami, Florida 33135 or CSA Standard W117.2. 

BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE, AND REPAIR PROCEDURES ARE

PERFORMED ONLY BY QUALIFIED INDIVIDUALS.

CUTTING SPARKS can
cause fire or explosion.

4.a..Remove fire hazards from the plasma cut-

ting or gouging area. If this is not possible,
cover them to prevent the cutting or gouging
sparks from starting a fire. Remember that

welding sparks and hot materials from plasma cutting or
gouging can easily go through small cracks and openings to
adjacent areas. Avoid cutting or gouging near hydraulic lines.
Have a fire extinguisher readily available.

4.b. Where compressed gases are to be used at the job site, spe-

cial precautions should be used to prevent hazardous situa-
tions. Refer to “Safety in Welding and Cutting” (ANSI
Standard Z49.1) and the operating information for the equip-
ment being used.

4.c. When not cutting or gouging, make certain no part of the elec-

trode circuit is touching the work or ground. Accidental con-
tact can cause overheating and create a fire hazard.

4.d. Do not cut or gouge tanks, drums or containers until the prop-

er steps have been taken to insure that such procedures will
not cause flammable or toxic vapors from substances inside.
They can cause an explosion even though they have been
“cleaned.” For information purchase “Recommended Safe
Practices for the Preparation for Welding and Cutting of
Containers and Piping That Have Held Hazardous
Substances”, AWS F4.1 from the American Welding Society
(see address above).

4.e. Vent hollow castings or containers before heating, cutting or

gouging. They may explode.

4.f.  Do nor fuel engine driven equipment near area where plasma

cutting or gouging.

ARC RAYS can burn.

2.a. Use safety glasses and a shield with the prop-

er filter and cover plates to protect your eyes
from sparks and the rays of the arc when per-
forming or observing plasma arc cutting or
gouging. Glasses,headshield and filter lens
should conform to ANSI Z87. I standards.

2.b. Use suitable clothing including gloves made from durable

flame-resistant material to protect your skin and that of your
helpers from the arc rays.

2.c. Protect other nearby personnel with suitable non-flammable

screening and/or warn them not to watch the arc nor expose
themselves to the arc rays or to hot spatter or metal.

ELECTRIC SHOCK can
kill.

1.a. The electrode and work (or ground) circuits

are electrically “hot” when the power source
is on. Do not touch these “hot” parts with
your bare skin or wet clothing. Wear dry,
hole-free gloves to insulate hands.

1.b. When the power source is operating voltages in excess of

250 volts are produced. This creates the potential for serious
electrical shock - potentially even fatal.

1.c. Insulate yourself from work and ground using dry insulation.

When cutting or gouging in damp locations, on metal frame-
work such as floors, gratings or scaffolds and when in posi-
tions such as sitting or lying, make certain the insulation is
large enough to cover your full area of physical contact with
work and ground.

1.d. Always be sure the work cable makes a good electrical con-

nection with the metal being cut or gouged. The connection
should be as close as possible to the area being cut or
gouged.

1.e. Ground the work or metal to be cut or gouged to a good elec-

trical (earth) ground.

1.f. Maintain the plasma torch, cable and work clamp in good,

safe operating condition. Replace damaged insulation.

1.g. Never dip the torch in water for cooling or plasma cut or

gouge in or under water.

1.h. When working above floor level, protect yourself from a fall

should you get a shock.

1.i. Operate the pilot arc with caution. The pilot arc is capable of

burning the operator, others or even piercing safety clothing.

1.j. Also see Items 4c and 6.

WARNING

PLASMA CUTTING or GOUGING can be hazardous.

FUMES AND GASES
can be dangerous.

3.a. Plasma cutting or gouging may produce

fumes and gases hazardous to health.
Avoid breathing these fumes and
gases.When cutting or gouging, keep your
head out of the fumes. Use enough ventila-

tion and/or exhaust at the arc to keep fumes and gases
away from the breathing zone. 

When cutting or gouging

on lead or cadmium plated steel and other metals or
coatings which produce highly toxic fumes keep expo-
sure as low as possible and below Threshold Limit
Values (TLV) using local exhaust or mechanical ventila-
tion. In confined spaces or in some circumstances, out-
doors, a respirator may be required. Additional precau-
tions are also required when welding on galvanized
steel.

3.b. Do not use plasma arc cutting or gouging in locations near

chlorinated hydrocarbon vapors coming from degreasing,
cleaning or spraying operations. The heat and rays of the arc
can react with solvent vapors to form phosgene, a highly
toxic gas, and other irritating products.

3.c. Gases used for plasma cutting and gouging can displace air

and cause injury or death. Always use enough ventilation,
especially in confined areas, to insure breathing air is safe.

3.d. Read and understand the manufacturer’s instructions for this

equipment and the consumables to be used, including the
material safety data sheet (MSDS) and follow your employ-
er’s safety practices. 

Apr. ‘93

Summary of Contents for PRO-CUT 40

Page 1: ...and Cutting Products Premier Manufacturer of Industrial Motors IM422 A October 1995 Safety Depends on You Lincoln plasma cutting equipment is designed and built with safety in mind However your overa...

Page 2: ...spatter or metal ELECTRIC SHOCK can kill 1 a The electrode and work or ground circuits are electrically hot when the power source is on Do not touch these hot parts with your bare skin or wet clothin...

Page 3: ...ocalized Electric and Magnetic Fields EMF Cutting or gouging current creates EMF fields around torch cables and cutting machines 8 b EMF fields may interfere with some pacemakers so opera tors having...

Page 4: ...et non inflammables 4 Des gouttes de laitier en fusion sont mises de l arc de soudage Se prot ger avec des v tements de protection libres de l huile tels que les gants en cuir chemise paisse pan talon...

Page 5: ...nts 10 Pilot Arc Discussion 11 Procedure Recommendations 11 General 11 Thin Gauge Sheet Metal 11 Expanded Metal 11 Thick Sections of Metal 12 In All Cases 12 Suggestions for Extra Utility from the PRO...

Page 6: ...e the information must be followed to avoid minor personal injury or damage to this equipment CAUTION Please Examine Carton and Equipment For Damage Immediately When this equipment is shipped title pa...

Page 7: ...minimum preheat temperature is recommended as a starting point Higher tempera tures may be used as required by the job conditions and or prevailing codes If cracking or excessive hardness occurs on th...

Page 8: ...pproximately 4 7 cfm 133 l min Failure to observe these precautions could result in excessive operating temperatures or damage to the torch HIGH FREQUENCY INTERFERENCE PROTECTION The PRO CUT 40 employ...

Page 9: ...baffle c Hold resistor body with electrically insulated glove DO NOT TOUCH TERMINALS Carefully lift mylar insulation Connect resistor terminals across two hex head cap screws in position shown Hold in...

Page 10: ...Safety LED is glowing push the Safety Reset button If there is no problem the LED will go off If there is a problem refer to Step 5 of the Test Step Chart and the Troubleshooting Guide D Set the Purg...

Page 11: ...e operating manual and on the machine The S19425 1 Drag Cup is recommended when the output control is set in the blue range to pro tect the torch from dross and improper arcing conditions Use proper c...

Page 12: ...System If it becomes absolutely necessary to cut through a very thick section the air flow at the regulator on the back of the machine may be raised to 75 psi 516 kPa to get a better cut result and m...

Page 13: ...cable jacket Replace if necessary Check to make sure that nothing is crushing the cable and blocking the flow of air through the air tube inside Also check for kinks in the cable periodically and rel...

Page 14: ...at rated input voltage Make ohmme ter checks only after power has been disconnected from machine and after capacitors have been dis charged Certain high voltage connections have been insulated with RT...

Page 15: ...E LED must be lit when refer to the section under that combination air is flowing 2 Check for proper TRIGGER SWITCH operation There should be continuity between J20 2 and J20 4 when the trigger switch...

Page 16: ...not correct replace the transformer T1 4 Check for 115VAC between J19 9 lead number 215B and J19 7 lead number 215D at the high frequency module 115VAC should be applied for approximately 1 2 second...

Page 17: ...y or greasy and in good shape LED begins blinking There was a brief arc Replace the consumables if necessary 2 Replace the PWM CONTROL BOARD 3 Replace the MICRO CONTROL BOARD The arc starts but sputte...

Page 18: ...BOARD Alternating AIR MALFUNCTION LED lights 1 Replace MICRO CONTROL BOARD The SAFETY LED is lit 1 The machine will not operate The machine senses that the nozzle is not in place or the operators coul...

Page 19: ...s on Switch PC Board 9 pos to 4 5 neg 9 neg to 4 5 pos Remove output load work to elec trode Test Result 1K ohms 100 ohms 100 ohms 1K ohms 1K ohms 100 ohms 100 ohms 1K ohms 100 ohms 500 ohms Conclusio...

Page 20: ...25 ohms high resistance 25 ohms high resistance 25 ohms high resistance 25 ohms high resistance 100 ohms 1K ohms 1K ohms 100 ohms 100 ohms 1K ohms 1K ohms 100 ohms 100 ohms 1K ohms 1K ohms 1K ohms 1K...

Page 21: ...1K ohms 100 ohms 1K ohms 100 ohms 1K ohms 100 ohms 1K ohms 100 ohms Conclusion OK Shorted OK Shorted OK Shorted OK Shorted OK Shorted Next Test Step 1 2 1 2 1 2 1 2 1 2 Repair Action Replace D9 In spa...

Page 22: ...ohms 1 K ohms 100 ohms 1K ohms 100 ohms 1K ohms 100 ohms 1K ohms Conclusion OK Shorted OK Open OK Open OK Open OK Open OK Open OK Open Next Test Step 1 2 1 2 1 2 1 2 1 2 1 2 1 2 Repair Action Replace...

Page 23: ...ed on 12 Connect an ohmmeter set for X1000 to the hex head screw terminals on the Switch PC board The meter will show the capacitors charging up The meter may take a minute or so to stabilize The valu...

Page 24: ...hine is on Normal OUTPUT ON On when there is voltage potential at the torch cutting or pilot Normal OUTPUT ON is blinking alternately with AIR PRESSURE when There is a problem with the microprocessor...

Page 25: ...ads shorted together 4 Foreign matter or interference behind the PC boards If PC board is visibly damaged mechanically such as a part vibrated off or was crushed inspect for cause then remedy before i...

Page 26: ...04 HIGH FREQ MODULE 607 R15 20K 5W C5 5 660VAC S2 S5 224B 224A LOCKED FAN THERMOSTAT 271 255B S3 S4 150 5W R14 255C THERMOSTAT B W W W 1 2 1 3 4 5 6 7 8 9 2 10 J4 1 3 4 5 6 7 8 2 J2 1 3 4 5 6 7 8 2 10...

Page 27: ...letin ED 80 or call 216 383 2259 and ask for the Welding School Registrar Lincoln Welding School BASIC COURSE 700 00 5 weeks of fundamentals There is a 10 discount on all orders of 50 00 or more for s...

Page 28: ...electrically live parts or electrode with skin or wet clothing Insulate yourself from work and ground No toque las partes o los electrodos bajo carga con la piel o ropa moja da Aislese del trabajo y...

Page 29: ...e Be und Entl ftung des Arbeitsplatzes Mantenha seu rosto da fuma a Use ventila o e exhaust o para remover fumo da zona respirat ria Turn power off before servicing Desconectar el cable de ali mentaci...

Page 30: ...e such as gun and cable assem blies water coolers FAS TRAK or MIG TRAK equipment Power Arc generator welders Wire Feed Module Factory Installed and field installed optional equipment TO OBTAIN WARRANT...

Reviews: