A-3
INSTALLATION
INSTALLATION OF PRISM® COMPACT (AD2455-1,
AD2455-2, AD2455-5, AD2455-6, & AD2455-9 ONLY)
TOOLS NEEDED
• 5/16" Nutdriver
• 9/16" Nutdriver
• Ladder/Lift
• Drill + 1/4" Drill Bit
Step 1 – Remove The 4X4 Wood Frame
Remove lag bolts and discard 4X4 wood frame.
FIGURE A.1
Step 2 – Install Fan Silencer
FIGURE A.2
FIGURE A.3
Wood frame bolted at
bottom of machine frame
(not pictured).
Open main door of unit and remove fan silencer (or
discharge grill and rain guard for AD2455-9). Remove it
from the packaging. Install fan silencer using 3/8 inch
bolts (See Figure A.2). For AD2455-9 only, place the
discharge grill on the fan outlet, then place the rain
guard on the discharge grill. Fasten them using 3/8 inch
bolts.
AD2455-1: 10 bolts
AD2455-2: 12 bolts
AD2455-5: 10 bolts
AD2455-6: 12 bolts
AD2455-9: 10 bolts
Step 3 – Compressed Air Connection
Connect Compressed air source to fitting (ISO 6150 B profile
- 1/4"). Adjust regulator pressure to 6 bar (87 psi) max.
AD2455-9 ONLY