![Lincoln Electric POWERTEC 300S Operator'S Manual Download Page 49](http://html1.mh-extra.com/html/lincoln-electric/powertec-300s/powertec-300s_operators-manual_1918477049.webp)
G-6
Technische Specificaties
POWERTEC 300S, 360S, 420S & 500S:
PRIMAIR
Nominaal primair vermogen
300S:
14.4 kVA @ 35% ID
360S:
16 kVA @ 40% ID
420S:
21 kVA @ 40% ID
Primaire spanning
230 / 400V
±
10%
Drie fase
500S:
29.9 kVA @ 40% ID
Frequentie
50 Hertz (Hz)
NOMINAAL SECUNDAIR VERMOGEN BIJ 40°C
Inschakelduur
(op basis van een10 min. Cyclus)
Lasstroom secundair
Lasspanning
300S:
35%
60%
100%
300A
225A
175A
29.0 Vdc
25.2 Vdc
22.7 Vdc
360S:
40%
60%
100%
350A
285A
220A
31.5 Vdc
28.2 Vdc
25.0 Vdc
420S:
40%
60%
100%
420A
345A
265A
35.0 Vdc
31.3 Vdc
27.3 Vdc
500S:
40%
60%
100%
500A
400A
315A
39.0 Vdc
34.5 Vdc
29.8 Vdc
SECUNDAIR BEREIK
Bereik lasstroom
Maximum Open spanning
300S:
30A - 300A
300S:
46 Vdc
360S:
30A - 350A
360S:
42 Vdc
420S:
30A - 420A
420S:
47 Vdc
500S:
30A - 500A
500S:
55 Vdc
AANBEVOLEN PRIMAIRE KABEL EN ZEKERINGEN
Primairezekering of zekeringautomaat
Primaire kabel
300S:
230V circuit: 40A traag
400V circuit: 25A traag
300S:
4 aderig, 4mm
2
360S:
230V circuit: 40A traag
400V circuit: 25A traag
360S:
4 aderig, 4mm
2
420S:
230V circuit: 63A traag
400V circuit: 32A traag
420S:
4 aderig, 6mm
2
500S:
230V circuit: 63A traag
400V circuit: 40A traag
500S:
4 aderig, 6mm
2
AFMETINGEN EN GEWICHT
Hoogte
Breedte
Lengte
Gewicht
300S:
790 mm
460 mm
925 mm
95 kg
360S:
360S
(water versie)
:
870 mm
870 mm
565 mm
700 mm
1030 mm
1030 mm
145 kg
171 kg
420S:
420S
(water versie)
:
870 mm
870 mm
565 mm
700 mm
1030 mm
1030 mm
154 kg
180 kg
500S:
500S
(water versie)
:
870 mm
870 mm
565 mm
700 mm
1030 mm
1030 mm
164 kg
190 kg
Werktemperatuur
-10°C tot +40°C
Opslagtemperatuur
-25°C tot +55°C