TROUBLESHOOTING
POWER WAVE
®
S500
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Lincoln Authorized Service Facility for technical troubleshooting assistance before you proceed.
WWW.LINCOLNELECTRIC.COM/LOCATOR
Observe all Safety Guidelines detailed throughout this manual
Light Condition
Meaning
Main control board status light and Input control board
Steady Green
System OK. Power source is operational, and is communicating normally with all healthy peripheral
equipment connected to its ArcLink network.
Blinking Green
Occurs during power up or a system reset, and indicates the POWER WAVE® S500 is mapping
(identifying) each component in the system. Normal for first 1-10 seconds after power is turned on, or
if the system configuration is changed during operation.
Fast Blinking Green
Indicates Auto-mapping has failed
Alternating Green and Red
Non-recoverable system fault. If the Status lights are flashing any combination of red and green,
errors are present. Read the error code(s) before the machine is turned off.
Error Code interpretation through the Status light is detailed in the Service Manual. Individual code
digits are flashed in red with a long pause between digits. If more than one code is present, the codes
will be separated by a green light. Only active error conditions will be accessible through the Status
Light.
Error codes can also be retrieved with the Power Wave Manager Utility available at www.power-
wavesoftware.com). This is the preferred method, since it can access historical information contained
in the error logs.
To clear the active error(s), turn power source off, and back on to reset.
Steady Red
Not applicable.
Blinking Red
Not applicable.
Status LED off
Not applicable.
TABLE E.1