B-4
OPERATION
B-4
CASE BACK CONTROLS
(See Figure B.2)
1. 115V / 15A DUPLEX RECEPTACLE AND
CIRCUIT BREAKER 1 (10 AMP):
Provides protec-
tion for the 115V auxiliary.
2. ARCLINK
®
RECEPTACLE AND CIRCUIT
BREAKER 2 (10 AMP):
Pin
Lead
Function
A
53A / 53B
Communication Bus L
B
54A / 54B
Communication Bus H
C
67A / 67B
Electrode Voltage Sense
D
52A / 52B
+40V DC
E
51A / 51B
0 VDC
3. SYNC-TANDEM CONNECTOR (4 PIN – MS
STYLE):
Pin
Lead
Function
A
WHITE
“Ready” H
B
BLACK/RED
“Ready” L
C
GREEN
“Kill” H
D
BLACK/GREEN
“Kill” L
4. OPTIONAL DEVICENET CONNECTOR (5 PIN –
SEALED MINI STYLE):
Pin
Lead
Function
2
894
+24 VDC DeviceNet
3
893
Common DeviceNet
4
892
DeviceNet H
5
891
DeviceNet L
5. ETHERNET CONNECTOR (RJ-45):
Used for
ArcLink
®
XT communication. Also used for diag-
nostics and reprogramming the Power Wave R350.
Pin
Function
1
Tr
2
Transmit -
3
R
4
---
5
---
6
Receive -
7
---
8
---
6. WIRE FEEDER RECEPTACLE (14-PIN):
For con-
nection to the Auto Drive 4R100/4R220 and PF10R
series wire feeders.
Pin
Lead
Function
A
539
Motor +
B
541
Motor -
C
521
So
D
522
Solenoid Common
E
845
Tach 2A differential signal
F
847
Single Tach input
G
841
+15V Tach supply
H
844
Tach common
I
Open
Reserved for future use
J
Open
Reserved for future use
K
842
Tach 1A differential signal
L
843
Tach 1B differential signal
M
846
Tach 2B differential signal
N
67G
Electrode Voltage Sense
7. OPTIONAL EXTERNAL I/O CONNECTOR:
Terminal Strip for making simple input signal connec-
tions. (See Figure B.2a)
The terminal strip is divided into three groups:
Group #1 -
TRIGGER
Group #2 -
FEED FORWARD/REVERSE
Group #3 -
SHUTDOWN INPUTS
When the Power Wave S350(CE) is controlled via
DeviceNet, the “
TRIGGER
” and “
Feed
” groups can
interfere with the welding sequence and should not be
used.
All inputs use "normally open" logic except the shut-
down group. The shutdown inputs use "normally
closed" logic, and are always enabled. Unused shut-
downs must be tied to the +15V supply for the shut-
down group. Machines are shipped from the factory
with jumpers installed on both shutdown inputs.
POWER WAVE
®
R350
FIGURE B.2
FIGURE B.2a