PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
OUTPUT PROBLEMS
The input fuses repeatedly fail or
the input circuit breakers keep trip-
ping.
1. Make certain the fuses or break-
ers are properly sized.
2.
Make certain the reconnect
panel is configured properly for
the applied voltage.
3. The welding procedure may be
drawing too much input current
or the duty cycle may be too
high. Reduce the welding cur-
rent and /or reduce the duty
cycle.
1. Check the reconnect switches
and associated wiring. See the
Wiring Diagram.
2. Perform the
Input Rectifier
Test.
3. Perform the
Switch Board
Test.
4. Perform the
Input Contactor
Test.