Retest a machine:
If it is rejected under test for any reason that requires you to remove any part which could affect the machine’s
electrical characteristics.
OR
If you repair or replace any electrical components.
INPUT IDLE AMPS AND WATTS
MAXIMUM OUTPUT VOLTAGES
TROUBLESHOOTING & REPAIR
F-88
F-88
POWER WAVE 455M/MSTT
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
RETEST AFTER REPAIR
Input Volts/Hertz
208/60
230/60
400/60
460/60
575/60
Maximum Idle Amps
4.0
3.3
2.1
2.0
1.8
Maximum Idle KW
0.45
0.45
0.45
0.45
0.45
Input Volts/Hertz
208/60
230/60
400/60
460/60
575/60
50-70 VDC
48.5 - 55 VDC
OCV
115 - 123 VAC
10 Amp Load
111 - 119 VAC
Output Terminals
- No load
X1 - X2
Aux. Trans #1
115 Volt Receptacles