POWER MIG 255
TROUBLESHOOTING & REPAIR
F-32
F-32
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
0 VOLTS
20.0 V
5 ms
MACHINE LOADED TO 250 AMPS AT 26 VDC
TYPICAL OUTPUT VOLTAGE WAVEFORM - MACHINE LOADED
This is a typical DC output voltage waveform
generated from a properly operating
machine. Note that each vertical division
represents 20 volts and that each horizontal
division represents 5 milliseconds in time.
The machine was loaded with a resistance
grid bank.
NOTE: Scope probes connected at machine
output terminals: (+) probe to electrode, (-)
probe to work.
Volts/Div . . . . . . . . . . . . . . . . . . 20 V/Div
Horizontal Sweep . . . . . . . . . . 5 ms/Div
Coupling . . . . . . . . . . . . . . . . . . . . . . DC
Trigger . . . . . . . . . . . . . . . . . . . . Internal
SCOPE SETTINGS