background image

Tested per AWS

Charpy V-Notch

Yield Strength

Tensile Strength

Elongation

ft•lbf (Joules)

psi (MPa)

psi (MPa)

(%)

@ -40ºF (-40ºC)

Requirements

P223/L-61

58,000 

70,000-95,000

22

20

AWS F7A4-EM12K

(400)

(483-655)

(27)

AWS A5.17-97

min.

min.

min.

As-welded 

Actual Test Results

63,400

77,300

31

93

(437)

(533)

(126)

Requirements

@ -20ºF (-29ºC)

P223/L-70

68,000 

80,000-100,000

20

20

AWS F8A2-EA1-A2

(469)

(552-689)

(27)

AWS A5.23-97

min.

min.

min.

As-welded 

Actual Test Results

79,800

93,900

25

39

(550)

(647)

(53)

MECHANICAL PROPERTIES 

– 

As Required per AWS A5.17-97/A5.23-97

NOTE: The multiple pass procedure shown above is specified in AWS A5.17-97/AWS A5.23-97 and was employed 
only for the purpose of AWS classification. The testing results and AWS classification shown should not be used to
determine the suitability of this flux/wire combination for service in limited pass applications. Actual procedural tests
should be conducted to verify the mechanical properties obtained on these applications.  

DEPOSIT COMPOSITION - 

As Required per AWS A5.17-97/A5.23-97

%C

%Mn

%Si

%S

%P

%Mo

%Cu

Requirements

P223/L-61
AWS F7A4-EM12K

Not Specified

AWS A5.17-97

Actual Test Results

0.08

1.38

0.43

0.003

0.011

0.06

Requirements

P223/L-70

0.12

1.40

.80

0.030

0.030

0.40-0.65

0.35

AWS F8A2-EA1-A2

max.

max.

max.

max.

max.

max.

AWS A5.23-97

Actual Test Results

0.08

1.33

0.38

0.009

0.014

0.51

0.09 

P223 FLUX

AWS A5.17-97: F7A4-EM12K and A5.23-97: F8A2-EA1-A2

P223 Flux   12/03

www.lincolnelectric.com

[2]

Summary of Contents for P223 FLUX

Page 1: ...at exceed most line pipe require ments Low diffusible hydrogen levels Manufactured under a quality system certified to ISO 9001 TYPICAL APPLICATIONS Oil and gas line pipe fabrication through X 80 grades Single pass or multiple pass welding Single arc or multiple arc up to 3 arc tandem welding Straight seam or spiral seam welding PRODUCT INFORMATION Basicity Index 1 60 Particle Size 12 Mesh 2 max 1...

Page 2: ... and was employed only for the purpose of AWS classification The testing results and AWS classification shown should not be used to determine the suitability of this flux wire combination for service in limited pass applications Actual procedural tests should be conducted to verify the mechanical properties obtained on these applications DEPOSIT COMPOSITION As Required per AWS A5 17 97 A5 23 97 C ...

Page 3: ...in m min volts amps in min m min Side 1 Lead Arc P223 L 61 or L 70 90 2 3 35 920 41 1 04 5 32 4 0 mm AC 1 1 2 38 1 mm 5 8 15 88 mm Trail Arc P223 L 61 or L 70 50 1 3 36 640 41 1 04 5 32 4 0 mm AC 1 1 2 38 1 mm 5 8 15 88 mm Side 2 Lead Arc P223 L 61 or L 70 100 2 5 36 980 38 97 5 32 4 0 mm AC 1 1 2 38 1 mm 5 8 15 88 mm Trail Arc P223 L 61 or L 70 48 1 2 41 620 38 97 5 32 4 0 mm AC 1 1 2 38 1 mm 5 8...

Page 4: ... expand or alter any warranty with respect to the sale of our products Lincoln Electric is a responsive manufacturer but the selection and use of specific products sold by Lincoln Electric is solely within the control of and remains the sole responsibility of the customer Many variables beyond the control of Lincoln Electric affect the results obtained in applying these types of fabrication method...