MAXIMUM OPEN CIRCUIT VOLTAGE
Open Circuit Volts
79.5/80 VDC
PERFORM METER ACCURACY TEST
RETEST AFTER REPAIR
Testing is required after the removal of any mechanical part that could affect the machine’s elec-
trical characteristics, or if any electrical components are repaired or replaced.
NO LOAD READINGS (FAN OFF)
Input Volts/Phase/Hertz
Maximum Idle Amps
Maximum Idle KW
380/3/50
15.0
2.0
400/3/50
20.0
2.25
415/3/50
25.0
2.5
460/3/60
6.5
2.0
500/3/50
17.0
2.0
575/3/60
6.5
2.0