CONTROL TRANSFORMER (T2) VOLTAGE TEST
MULTI-SOURCE
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
NOTE:
If the secondary voltage is not pre-
sent at terminal #X3 but is present at
terminal #X2 the internal thermostat
is faulty. See Figure F.2.
7. Replace any leads previously removed.
8. Replace right side and roof.
X3
Thermostat
X2
X1
Secondary
FIGURE F.2. Thermostat
TROUBLESHOOTING & REPAIR