Error messages: 

 

Message 

Description 

Misadjustment(s) 

Corrective Action 

Unstable Welding 
Voltage 

The generator is unable to 
deliver the pre-set value 
(voltage) requested by the 
wire feeder. 
 
It can appears: 
1.  During welding: 

 
 
 
 
 
 

 

Check that welding pre-set 
parameters (WFS and 
Voltage) matches the 
application (wire diameter, 
thickness, gas…). 

 

 

Check the polarity switch 
position of the generator 
correspond to the polarity 
of the wire feeder 
connection. 

 

 

Check the remote control 
switch of the generator set 
on “Remote” position. 

 

 

Check if pre-set 
parameters are not above 
the specified limit of the 
generator. 

 
 
 
 
 
 

 

Adjust parameters. 

 
 
 
 
 

 

Correct polarity switch 
position and wire feeder 
polarity connection. 

 
 
 

 

Select “remote” position. 

 
 
 

 

Reduce the parameters or 
use an higher rating 
generator. 

Wire Feed Jam 

Motor is at maximum 
power and is not able to 
maintain the pre-set WFS 
value. 

 

Verify wire can move freely 
in cable. 

 

 

Verify spool brake is not 
set too high. 

 

Clean or replace the liner. 

 
 

 

Adjust spool brake. 

Water Flow Too Low 

The wire feeder has 
detected: 

 

No water flow. 

 

Too low water flow 
(less than 0.7 
liter/min). 

 

Check if the water cooler is 
on and filled up with 
coolant. 

 

 

Check the water circuit 
including water cooled 
torch connection. 

 

Fill up and switch on water 
cooler. 

 
 

 

Remove blockage in water 
circuit. 

Water Flow Detected 

The wire feeder has 
detected water flow while 
the setting in select menu 
is water cooler “no”. 

 

The setting of water cooler 
is wrong in the select 
menu. 

 
Note:  In this case, flow meter 
protection is not used. 

 

Select the correct setting of 
the water cooler in select 
menu. 

 

English  

English 

11 

Summary of Contents for LINC FEED 37

Page 1: ...IM1094 09 2016 REV08 LINC FEED 37 38 OPERATOR S MANUAL ENGLISH Lincoln Electric Bester Sp z o o ul Jana III Sobieskiego 19A 58 263 Bielawa Poland www lincolnelectric eu...

Page 2: ...LINC FEED 38 conforms to the following directives 2014 35 EU 2014 30 EU and has been designed in compliance with the following standards EN 60974 5 2013 EN 60974 10 2014 20 04 2016 Piotr Spytek Operat...

Page 3: ...ture reference record in the table below your equipment identification information Model Name Code Serial Number can be found on the machine rating plate Model Name Code Serial number Date Where Purch...

Page 4: ...clamp to avoid the risk of accidental arc ignition ELECTRIC AND MAGNETIC FIELDS MAY BE DANGEROUS Electric current flowing through any conductor creates electric and magnetic fields EMF EMF fields may...

Page 5: ...may result in injury or equipment damage Read the section on electromagnetic compatibility in this manual Do not operate in areas with an ambient temperature greater than 40 C Duty cycle The duty cyc...

Page 6: ...or Lincoln Electric Maintenance or repairs performed by unauthorized service centers or personnel will null and void the manufacturer s warranty The frequency of the maintenance operations may vary i...

Page 7: ...Mode LF 38 While pressing the Prog button rotate the left knob until NON SYNERGIC appears on the display Before Welding Pre Set Pre Set Wire Feed Speed Meters Minute Adjust with left knob Pre Set Weld...

Page 8: ...select the appropriate wire diameter Steel 80 20 0 8 1 0 1 2 mm Stainless 98 2 0 8 1 0 1 2 mm Metal Cored 98 2 1 2 1 6 mm Flux Cored 80 20 1 2 1 6 mm Flux Cored CO2 1 2 1 6 mm AlMg 100 Arg 1 2 1 6 mm...

Page 9: ...hape at the end of the weld NO YES 4 Strokes 4 Strokes Crater WFS Welding WFS m min Crater Voltage Welding Voltage Volts Hot Soft Start WFS Allows to set higher or lower welding parameters to improve...

Page 10: ...arameters into the selected memory WRITE into memory The status of the memory becomes Used READ You can read the welding parameters allready saved into the selected memory ERASE memory If you confirm...

Page 11: ...ns Only the memory locations that have been used will be available Once selected begin welding Welding While welding in Memory Mode the Non Synergic Voltage or the Synergic Trim values can be varied a...

Page 12: ...ton Enter Lock Or Unlock NO Confirm NO to Exit this menu YES Confirm YES to Enter the menu Lock Or Unlock Select 1 st Digit of your code Confirm 1st Digit Select 2 nd Digit of your code Confirm 2 nd D...

Page 13: ...dard value 2 Value used to determine the acceleration of the wire between the Cold inch WFS and the Welding WFS PRODUCT TYPE Not used Shows Product Type LF 37 or LF 38 SN Not used Shows Product Serial...

Page 14: ...mote position Reduce the parameters or use an higher rating generator Wire Feed Jam Motor is at maximum power and is not able to maintain the pre set WFS value Verify wire can move freely in cable Ver...

Page 15: ...be sure that all equipment in the area is compatible This may require additional protection measures The dimensions of the work area to consider will depend on the construction of the area and other...

Page 16: ...e Use only the parts marked X in the column under the heading number called for in the assembly page indicate a change in this printing First read the Part List reading instructions above then refer t...

Reviews: