
POWER WAVE 450
TECHNICAL SPECIFICATIONS - POWER WAVE 450
INPUT - THREE PHASE 50/60 HZ. ONLY
Input Voltages:
200
230
400
460
575
Input Currents
@ 500A/40 VDC
87
76
44
38
32
@ 450A/38 VDC
75
65
38
32
28
RATED OUTPUT
Duty Cycle
Amps
Volts at Rated Amperes
200 - 60% Duty Cycle
500
40 VDC
230/400/460 - 60% Duty Cycle
500
40 VDC
460/575 - 60% Duty Cycle
500
40 VDC
200 - 100% Duty Cycle
450
38 VDC
230/400/460 - 100% Duty Cycle
450
38 VDC
460/575 - 100% Duty Cycle
450
38 VDC
OUTPUT
Constant Open
Continuous
Process
Circuit Voltage
Current Range
Current Ranges
75 Volts
5-540 Amps
GMAW 50-540 Amps
FCAW 40-540 Amps
STICK 30-540 Amps
Pulse
Pulse
Pulse and Background
Pulse
Current Range
Voltage Range
Time Range
Frequency
5-750 Amps
5-55 Volts
100 Microsec - 3.3 Sec
0.15 - 1000 Hz
RECOMMENDED INPUT WIRE AND FUSE SIZES
Type 75°C
Type 75°C
Type 75°C
Input
Duty
Input Ampere
Copper Wire in
Ground Wire in
(Super Lag)
Voltage/
Cycle
Rating on
Conduit
Conduit
or Breaker
Freqency
Nameplate
AWG[IEC]
AWG[IEC]
Size (Amps)
Sizes (MM
2
)
Sizes (MM
2
)
200/50-60
60%
87
4 (25)
8 (10)
120
230/50-60
60%
76
4 (25)
8 (10)
100
400/50-60
60%
44
8 (10)
10 (6)
50
460/50-60
60%
38
8 (10)
10 (6)
50
575/50-60
60%
32
8 (10)
10 (6)
50
200/50-60
100%
75
4 (25)
8 (10)
100
230/50-60
100%
65
4 (25)
8 (10)
100
400/50-60
100%
38
8 (10)
10 (6)
50
460/50-60
100%
32
8 (10)
10 (6)
50
575/50-60
100%
28
8 (10)
10 (6)
40
PHYSICAL DIMENSIONS
Height
Width
Depth
Weight
905 mm
515 mm
1010 mm
138 kg
35.6 in.
20.3 in.
39.8 in.
304 lbs.
OPERATING TEMPERATURE RANGE STORAGE TEMPERATURE RANGE
0° to 40°C
-50° to 85°C
INSTALLATION
A-1
A-1