B-9
OPERATION
B-9
Rev. 13
INVERTEC
®
CC400-T/TP
List of parameters and Factory Configuration program:
INVERTEC CC400-TP
parameters
Mode
Displayed
parameter name
Parameter
Selectable Value
Range
step
Factory
Configuration
Displayed value
GTAW
Preflow
0.1~15S
0.1S
0.5S
Current selected
value (s)
Start Current
0~100%
1
50%
Current selected
value (%)
Upslope
0~15S
0.1S
0.5S
Current selected
value(s)
Set Current
5~400A
1A
150A
Current selected
value(A)
Duty Cycle
5%~95%
1
50%
Current selected
value(%)
Frequency
Not
Current selected
value (Hz)
LF
0.2~20Hz
0.1Hz
2Hz
HF
10~300Hz
1Hz
30Hz
Background
0~100%
1
50%
Current selected
value (%)
Downslope
0~15S
0.1S
0.5S
Current selected
value (s)
Crater
0~100%
1
50%
Current selected
value(%)
Postflow
0.1~15S
0.1S
0.5S
Current selected
value(s)
SMAW
Uo
Set Current
5~400A
1A
150A
Current selected
value(A)
---
Hot start
0~10
1
0
Current selected
value(proportion)
---
Arc force
0~10
1
5
Current selected
value(proportion)
SPOT TIG
Set Current
5~400A
1A
150A
Current selected
value(A)
Spot time
0.1~5S
0.1S
1S
Current selected
value(s)
Note
:
when restoring factory settings, the six subitems
、
、
、
、
、
will
be set into 0.