![Lincoln Electric INVERTEC 275S Operator'S Manual Download Page 3](http://html1.mh-extra.com/html/lincoln-electric/invertec-275s/invertec-275s_operators-manual_1919028003.webp)
English
1 English
Technical Specifications
NAME
INDEX
INVERTEC 275S
K14242-1
INPUT
Input Voltage U
1
EMC
Class
INVERTEC
275S
400V +/- 15% 3 phases
A
I
1eff
I
1max
9.8A 15,3A
INVERTEC
275S
Input Power at Rated Cycle
Input Amperes I
1max
PF
(400V)
7,1 kVA (@100%)
10,1A
0,79
9,1 kVA (@60%)
12,9A
0,85
11 kVA (@25%)
15,3A
0,89
RATED OUTPUT
Duty Cycle 40°C
(based on a 10 min. period)
Output Current I
2
GTAW
100% 200A
60% 230A
40% 270A
SMAW
100% 180A
60% 230A
25% 270A
OUTPUT RANGE
Welding Current Range
Peak Open Circuit Voltage U
0
GTAW
5 - 270A
70V
SMAW
5 - 270A
RECOMMENDED INPUT CABLE AND FUSE SIZES
Fuse Type gR or Circuit Breaker Type Z
Power Lead
INVERTEC
275S
16A, 400V AC
4 Conductors, 1,5mm
2
DIMENSIONS AND WEIGHT
Weight Height Width
Length
INVERTEC
275S
14,1Kg
360 mm
230 mm
498 mm
Protection Rating
Maximum Gas Pressure
INVERTEC
275S
IP23
0,5 MPa (5 bar)
Operating Temperature
Storage Temperature
from -10°C to +40°C
from -25°C to +55°C