background image

English 8 English 

 

 
 

Ascent Slope 

By pressing function keys 31 e 32 the luminous indicator 
is position at 21 - Picture 1 Page 6.); then by activating 
the knob 30, the time to reach the nominal current 
welding in TIG modality is set up. The value range is 
between 0 and 10 seconds. 
 

 

 
 

Nominal Current Welding 

By pressing function keys 31 e 32 the luminous indicator 
is position at 22 - Picture 1 Page 6.); then by activating 
the knob 30, the value for the nominal current welding 
for alvl the available modalities is set up. The value 
range is between 5A and 220A in electrode mode; 5A 
and 220A. 

 

 
 

Reduced Current/ Basic Current. 

By pressing function keys 31 e 32 the luminous indicator 
is position at 23 - Picture 1 Page 6.); then by activating 
the knob 30, the value for the reduced current in the 
Four Times mode is set up. If the TIG mode is pressed 
(either Two or Four Times) the pulsation of the basic 
current is set up. The value range is between the 
nominal current welding and the 10% of that same value. 
 

 

 
 

Spot Time 

By pressing function keys 31 e 32 the luminous indicator 
is position at 24 - Picture 1 Page 6.); then by activating 
the knob 30, the time length for the spot impulse is set 
up in seconds. TIG The value range is between 0,1 and 
10 seconds. 
 

 

 
 

Wave-shaped Balance 

By pressing function keys 31 e 32 the luminous indicator 
is position at 25 - Picture 1 Page 6.); then by activating 
the knob 30, the balance of the different wave shapes 
pressed on TIG is set up. 
The wave-shaped balance can be set up in a value 
ranging from 1 and 99 for frequencies between 0,3 Hz 
and 15 Hz. The range decreases linearly for higher 
frequencies (up to 250 Hz) up to range between 30 and 
70 (See - Picture 2 Page 6.). 
 

 

 
 

Wave-shaped balance 

Picture 2. 
 

 

 

WAVE-SHAPED BALANCE 

 

Descent Slope 

By pressing function keys 31 e 32 the luminous indicator 
is position at 27 - Picture 1 Page 6.); then by activating 

20 

21 

25 

22 

23 

24 

FREQUENCY 

Summary of Contents for INVERTEC 175TP

Page 1: ...800036917 05 2019 REV02 INVERTEC 175TP OPERATOR S MANUAL ENGLISH Lincoln Electric Bester Sp z o o ul Jana III Sobieskiego 19A 58 263 Bielawa Poland www lincolnelectric eu...

Page 2: ...r future reference record in the table below your equipment identification information Model Name Code Serial Number can be found on the machine rating plate Model Name Code Serial number Date Where P...

Page 3: ...A Maximum consumption 21 A 14 A SECONDARY SIDE Open circuit voltage 50 V Peak voltage 10kV Welding current 5 A 175 A Duty cycle 25 175 A Duty cycle 60 140 A Duty cycle 100 120 A 130 A MISCELLEANOUS P...

Page 4: ...ontrol equipment for industrial processes Equipment for calibration and measurement Personal medical devices like pacemakers and hearing aids Check the electromagnetic immunity for equipment operating...

Page 5: ...AGNETIC FIELDS MAY BE DANGEROUS Electric current flowing through any conductor creates electric and magnetic fields EMF EMF fields may interfere with some pacemakers and welders having a pacemaker sha...

Page 6: ...y be subjected to physical damage or the welding process including sparks and heat sources HF CAUTION The high frequency used for contact free ignition with TIG GTAW welding can interfere with the ope...

Page 7: ...BEFORE INSERTING THE MAINS PLUG IN ORDER TO AVOID THE FAIL OF POWER SOURCE CHECK IF THE MAINS CORRESPONDS TO THE WISHED MAIN SUPPLY On off switch This switch has two positions ON I and OFF O THIS CLAS...

Page 8: ...minous indicator reaches the position on symbol 2 Picture 1 Page 6 If you press the torch button you will get a high voltage discharge that allows the arc fusing TIG DC Welding with Lift Start By pres...

Page 9: ...circuit Output stage failure Eliminate the short circuit Call after sales service PiF The inverter stage does not work properly NOTE whenever all the panel luminous indicators remain on or off simulta...

Page 10: ...wo or Four Times the pulsation of the basic current is set up The value range is between the nominal current welding and the 10 of that same value Spot Time By pressing function keys 31 e 32 the lumin...

Page 11: ...inous indicator is position at 28 Picture 1 Page 6 then by activating the knob 30 the value for the final current on the TIG Four Times mode is set up The value range is between I Min and the nominal...

Page 12: ...for more than three seconds the key 31 At this point desired program is loaded the recall is accompanied by long beep The exit from this state is possible in three ways 1 Recalling a program 2 Inactiv...

Page 13: ...G WELDING FAULTS POSSIBLE CAUSES CONTROLS AND REMEDIES The generator does not weld the digital switch is not lit The main switch is off The power lead is interrupted lack of one or two phases Other Sw...

Page 14: ...ny is manufacturing and selling high quality welding equipment consumables and cutting equipment Our challenge is to meet the needs of our customers and to exceed their expectations On occasion purcha...

Page 15: ...he Lincoln Electric Service Department for any code number not listed Use the illustration of assembly page and the table below to determine where the part is located for your particular code machine...

Reviews: