Lincoln Electric INVERTEC 170TPX AUS Operator'S Manual Download Page 12

English  

English 

10

Remote LED: 

 

This indicator will turn on when a Remote command is 
connected to the machine via the remote control 
connector. 
 
If a Remote command is connected to the Machine, the 
Output Current knob operates in two different modes: 
STICK and TIG: 
 

 

STICK mode:

 with a Remote command 

connected the output of the machine is ON.  A 
Remote Amptrol or Pedal are allowed (trigger is 
ignored). 

 

 

 

  

 

 
Connecting the Remote command excludes the 
Output Current Knob of the Machine’s user 
interface.  Through the Remote command is 
available the full Output Current Range. 

 

 

TIG mode:

 in Local and remote mode the 

output of the machine is OFF.  A Trigger is 
necessary to enable the output. 

 

  

  

 

 

  

 

 

For 170TX/TPX: 

The Output Current range 

selectable from the Remote command depends by 
the Machine’s user interface Output Current Knob.  
Eg.: if  the Output Current is set to 100A with the 
Machine’s user interface Output Current Knob, the 
Remote command will adjust the Output Current 
from a minimum of 2A to a maximum of 100A. 
 

For 220TPX:

 The Output Current range selectable 

from the Remote command depends by the 
Machine’s user interface Output Current Knob.  Eg.: 
if  the Output Current is set to 100A with the 
Machine’s user interface Output Current Knob, the 
Remote command will adjust the Output Current 
from the minimum current to a maximum of 100A. 
The output current set by Output Current Knob is 
shown for 3 second whenever the knob is moved. 
After the 3 second the value shows is the current 
select by the Remote command. 
 
Remote Pedal: For a correct use, the “option 30” 
must be enabled in the setup menu: 

 

2-step sequence is automatically selected 

 

Upslope / Downslope ramps and Restart are 

disabled. 

 

Spot, Bi-Level and 4-step functions aren’t 

selectable 

 
(Normal operation is restored when the Remote 
command is disconnected.) 

 

Thermal LED: 

 

This indicator will turn on when the machine is 
overheated and the output has been disabled.  This 
normally occurs when the duty cycle of the machine has 
been exceeded.  Leave the machine on to allow the 
internal components to cool.  When the indicator turns 
off, normal operation is again possible. 
 

VRD LED (enabled on Australian Machines only): 

 

This machine is provided by VRD (Voltage Reduction 
Device) function:  this reduces the voltage at the output 
leads. 
 

The VRD function is enabled by factory default only 
on machines that meet the AS 1674.2 Australian 
Standards.

  (C-Tick logo " " on/near the Rating Plate 

applied on the machine). 
 

The VRD LED is ON

 when the Output Voltage is below 

12V with the Machine at idle (no welding time). 
 
For others machines this function is disabled (the LED is 
always OFF). 
 

Mode Pushbutton: 

 

This pushbutton changes the welding modes of the 
machine: 

 Stick 

 

(SMAW) 

  Lift TIG  

(GTAW) 

  HF TIG  

(GTAW) 

 Spot 

TIG 

  (GTAW) 

The Spot TIG feature is selectable only if the “option 
10” is previously enabled in the Setup Menu.  See 
“Setup menu” section for options enabling / disabling. 

 
Each welding mode is is detailed in the Operating 
instruction section. 
 

Trigger Mode Pushbutton: 

 

This pushbutton changes the trigger sequence in TIG 
welding mode: 

 

2-step / 4-step with restart  This option is not 
selectable by the Trigger Pushbutton and, if 
enabled, operates with 2 or 4 step mode: 

 

 

This indicator will turn on if the restart option is 
enabled for the current TIG trigger mode.  Restart 
can be enabled separately for 2-step and 4-step 
modes from the Setup Menu.  More information 
about restart is available in the Operating instruction 
section. 

 2-step 

 4-step 

 Bi-Level 

Summary of Contents for INVERTEC 170TPX AUS

Page 1: ...IM2050 10 2019 REV08 INVERTEC 170TX 170TPX 220TPX OPERATOR S MANUAL ENGLISH Lincoln Electric Bester Sp z o o ul Jana III Sobieskiego 19A 58 263 Bielawa Poland www lincolnelectric eu...

Page 2: ...e Code Serial Number can be found on the machine rating plate Model Name Code Serial number Date Where Purchased ENGLISH INDEX Technical Specifications 170TX TPX CE model 1 Technical Specifications 17...

Page 3: ...ne Duty Cycle 40 C based on a 10 min period Output Current I2 Output Voltage U2 230Vac 100 Stick 110A 24 4V 100 TIG 130A 15 2V 30 Stick 160A 26 4V 35 TIG 170A 16 8V OUTPUT RANGE Welding Current Range...

Page 4: ...e 40 C based on a 10 min period Output Current I2 Output Voltage U2 230Vac 100 Stick 110A 24 4 V 100 TIG 130A 15 2 V 30 Stick 160A 26 4 V 30 TIG 170A 16 8 V 240Vac 15A circuit braker 100 Stick 75 A 23...

Page 5: ...n a 10 min period Output Current I2 Output Voltage U2 230Vac 100 Stick 130 A 25 2 V 100 TIG 150 A 16 0 V 35 Stick 170 A 27 2 V 25 TIG 220 A 18 8 V 115Vac 100 Stick 90 A 23 6 V 100 TIG 110 A 14 4 V 35...

Page 6: ...ne Radio and or television transmitters and receivers Computers or computer controlled equipment Safety and control equipment for industrial processes Equipment for calibration and measurement Persona...

Page 7: ...in or adjacent to the work area and the machine Radio and or television transmitters and receivers Computers or computer controlled equipment Safety and control equipment for industrial processes Equ...

Page 8: ...or creates electric and magnetic fields EMF EMF fields may interfere with some pacemakers and welders having a pacemaker shall consult their physician before operating this equipment CE COMPLIANCE Thi...

Page 9: ...e part to touch a gas cylinder Gas cylinders must be located away from areas where they may be subjected to physical damage or the welding process including sparks and heat sources HF CAUTION The high...

Page 10: ...e technical specification section of this manual Input Supply From Engine Driven Generators The machine is designed to operate on engine driven generators as long as the auxiliary can supply adequate...

Page 11: ...enter Green Mode Green Mode Green Mode is a feature that puts the machine in a stand by condition The output is disabled The fan is turned OFF Only the Power ON LED remains ON A moving red dash is sh...

Page 12: ...pslope Downslope ramps and Restart are disabled Spot Bi Level and 4 step functions aren t selectable Normal operation is restored when the Remote command is disconnected Thermal LED This indicator wil...

Page 13: ...welding mode this command is disabled When Pulse is active is possible to set Duty cycle Frequency Hz and Background parameters During TIG welding is not possible switch ON or OFF the Pulse command i...

Page 14: ...Voltage Press SEL Press SEL Wait 4s or start welding to store the changes Current Lift TIG GTAW welding To select Lift TIG welding Action Visualization Press MODE several times until the LED above lig...

Page 15: ...final current value after the Downslope For an explanation of the Crater operation refer to the trigger sequences explained below 7 POSTFLOW In the TIG welding modes this function controls the shield...

Page 16: ...ease the output current at a controlled rate or downslope time until the Crater current is reached and the output of the machine is turned OFF After the arc is turned OFF the gas valve will remain ope...

Page 17: ...ch trigger is quickly pressed and released from step 3A it is possible to press and hold the TIG torch trigger another time to end the downslope time and maintain the output current at the Crater curr...

Page 18: ...modes corresponding to different states of the machine are identified Before welding pressing the UP or DOWN key causes a change of value of the Set current While welding pressing the UP or DOWN key...

Page 19: ...ult valid only for 220TPX To change a setting push SEL then rotate the encoder Output Current Knob to modify the setting and push SEL again to confirm the new value Error Codes and troubleshoting If a...

Page 20: ...ected from the machine before each maintenance and service After each repair perform proper tests to ensure safety Customer Assistance Policy The business of The Lincoln Electric Company is manufactur...

Page 21: ...ue Hz Background ONLY 220 170 TPX 30 10 90 step 1 Current selected value of set current Downslope 0s 0 20s step 0 1s Current selected value s Crater 30 5 100 step 1 Current selected value of set curre...

Page 22: ...r is not listed Contact the Lincoln Electric Service Department for any code number not listed Use the illustration of assembly page and the table below to determine where the part is located for your...

Page 23: ...alve Conn 35 50 K10513 9 z TIG torch LT 9 G 110A z 4m or 8m Ergo K10513 26 z TIG torch LT 26 G 180A z 4m or 8m Ergo K10529 26 z TIG torch LTP 26 G 180A z 4m 8m or 12m Ergo K10529 26 zX TIG torch LTP 2...

Reviews: