ACCESSORIES

C-1

OPTIONAL ACCESSORIES

AND COMPATIbLE  EQUIPMENT

Factory Installed 

Electrical  Holder and Cable Assembly
Work Cable and Clamp
Strap Packet
Instruction Manual 

Field Installed

PTA-17V  TIG  Torch  -

150 Amp  air-cooled  compact

and  durable  Tig  Torch  with  integral  gas  valve  for  gas
control at the torch. The following 1-piece cable torches
can be used with a K960-2 adapter:

• K1782-6 (12.50 Ft.) 1-Piece Cable
• K1782-8 (25.0 Ft.) 1-Piece Cable

PTA-17FV TIG Torch - 

150 Amp  Gas  Valve  flexible
head torch: 

• K1782-11 (25.0 Ft.) 1-Piece Cable
• K1782-13 (12.5 Ft.) 1-Piece Ultra Flex Cable

K960-2-TIG  Torch  Adapter  - 

for  connection  of  PTA-

17V torches (1-piece cable) to power sources without
gas passing through the Twist Mate connection.

CAbLE PLUGS

K852-25 -

Cable Plug Kit attaches to welding cable to

provide quick disconnect from machine.

TIG  Torch  Parts  Kit  - 

A  Parts  kit  is  available  for  the

PTA-17 TIG torch.  This kit includes back cap, collets,
collet bodies, nozzles, and tungtens.

Order KP508

for PTA-17 torches

See publication E12.150 for parts kits breakdown.

Cut Length Consumables -

TIG welding filler metals

are  available  for  welding  stainless  steel,  mild  steel,
aluminum and copper alloys. See publication C9.10.

INVERTEC® 100S

Summary of Contents for INVERTEC 100S

Page 1: ...9 U S A TEL 216 481 8100 FAX 216 486 1751 WEB SITE www lincolnelectric com Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind However your overal...

Page 2: ...KER WEARERS SHOULD CONSULT WITH THEIR DOCTOR bEFORE OPERATING Read and understand the following safety highlights For additional safety information it is strongly recommended that you purchase a copy...

Page 3: ...cooling 3 h Never simultaneously touch electrically hot parts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both welder...

Page 4: ...s to adjacent areas Avoid welding near hydraulic lines Have a fire extinguisher readily available 6 b Where compressed gases are to be used at the job site special precautions should be used to preven...

Page 5: ...opri s et non inflammables 4 Des gouttes de laitier en fusion sont mises de l arc de soudage Se prot ger avec des v tements de protection libres de l huile tels que les gants en cuir chemise paisse pa...

Page 6: ...he situation with the technical assistance of the manufacturer In some cases this remedial action may be as simple as earthing grounding the welding circuit see Note In other cases it could involve co...

Page 7: ...s Welding Cables The welding cables should be kept as short as possible and should be positioned close together running at or close to floor level Equipotential Bonding Bonding of all metallic compone...

Page 8: ..._______________________ Date Purchased___________________________________________________________________________ Where Purchased_______________________________________________________________________...

Page 9: ...B 2 Making the Weld B 3 B 4 ________________________________________________________________________ Accessories Section C Optional Accessories and Compatible Equipment C 1 Factory Field Installed C...

Page 10: ...SIONS TEMPERATURE RANGES OPERATING TEMPERATURE RANGE 10 C to 40 C STORAGE TEMPERATURE RANGE 25 C to 55 C RECOMMENDED INPUT WIRE AND FUSE SIzES FOR MAXIMUM RATED OUTPUT INPUT VOLTAGE FREQUENCY Hz 120 6...

Page 11: ...ay result in injury or equipment damage Read the section on electromagnetic compatibility in this manual Do not operate in areas with an ambient tempera ture greater than 40 C STACKING The INVERTEC 10...

Page 12: ...RTEC 100S A 3 120V INPUT The rated output of the Invertec 100S is available when connected to a 20A branch circuit When con nected to a branch circuit with lower ampacity lower welding current and dut...

Page 13: ...exhaust to remove fumes from breathing zone ARC RAYS can burn Wear eye ear and body protection WELDING CUTTING and GOUGING SPARKS can cause fire or explosion Keep flammable material away Do not weld c...

Page 14: ...is established in this gap and is held and moved along the joint to be welded melting the metal as it is moved ELECTRIC ARC See Figure B 4 Action that takes place in the electric arc FIGURE b 4 CONTR...

Page 15: ...well as hot and cannot be looked at with the naked eye without risking painful injury A very dark lens specifically designed for arc welding must be used with a hand or face shield whenever viewing th...

Page 16: ...way of an electric arc Unlike stick welding in which the electrode is consumed in the arc the tung sten electrode is not consumed Instead filler metal is added to the weld by manually dipping a filler...

Page 17: ...82 11 25 0 Ft 1 Piece Cable K1782 13 12 5 Ft 1 Piece Ultra Flex Cable K960 2 TIG Torch Adapter for connection of PTA 17V torches 1 piece cable to power sources without gas passing through the Twist Ma...

Page 18: ...can be serviced Discharging is done automatically by the machine each time the power is switched off However you must allow the machine to sit for at least 5 minutes to allow time for the process to...

Page 19: ...beled POSSIBLE CAUSE lists the obvious external possibilities that may contribute to the machine symptom Step 3 RECOMMENDED COURSE OF ACTION This column provides a course of action for the Possible Ca...

Page 20: ...gh progression speed 2 Welding current too low 3 Narrow chamfering 1 Arc too short 2 Current too low 1 Humidity in electrode 2 Long arc 1 Current too high 2 Dirty materials 3 Hydrogen in weld present...

Page 21: ...OF ACTION Oxidation Tungsten inclusions Porosity Hot cracking 1 lnsufficient gas 2 No protection on the back side 1 lncorrect electrode sharpening 2 Electrode too small 3 Operating failure contact of...

Page 22: ...nit has been operated beyond its capacity rating 2 Airflow through machine is restrict ed or fan has failed 1 Check the output current poten tiometer and replace it if neces sary 2 Verify output cable...

Page 23: ...may not be accurate for all machines covered by this manual The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels If the diagram is illegible write to...

Page 24: ...RBEITGEBERS l Do not touch electrically live parts or electrode with skin or wet clothing l Insulate yourself from work and ground l No toque las partes o los elec trodos bajo carga con la piel o ropa...

Page 25: ...nes de travail l Vermeiden Sie das Einatmen von Schweibrauch l Sorgen Sie f r gute Be und Entl ftung des Arbeitsplatzes l Mantenha seu rosto da fuma a l Turn power off before servic ing l Desconectar...

Page 26: ...s Leader in Welding and Cutting Products Sales and Service through Subsidiaries and Distributors Worldwide Cleveland Ohio 44117 1199 U S A TEL 216 481 8100 FAX 216 486 1751 WEB SITE www lincolnelectr...

Reviews: