20
–
OUTPUT CONTROL “LOCAL-REMOTE” SWITCH
The Output Control toggle switch on the control panel
labeled “Local-Remote” gives the operator the option
of controlling the output at the machine control panel
or at a remote station. For remote control, the toggle
switch is set in the “Remote” position and controlled at
the wire feed unit control, or by connecting a K775
control to terminals 75, 76, and 77 on the terminal
strip at the front of the machine, or by connecting a
K857 control with a K864 adapter to the 14-pin con-
nector on the front of the machine. For control at the
machine control panel (Output Voltage control dial),
the toggle switch is set in the “Local” position.
(Exception: When used with an Ln-9, Ln-9 GMA or
nA-5 wire feeder, the Output Control switch must be
in the “Remote” position or automatic shutdown of the
Ln-9 or nA-5 may occur.)
POLARITY SELECTION
Polarity selection is made by appropriately connecting
the electrode and work welding cables to either the
“
+
” stud or to the “
-
” stud. Select “Voltmeter” switch
for “
+
” or “
-
” electrode for the remote (#21) work sens-
ing lead.
VOLTMETER SWITCH
Select “
+
” for positive electrode or “
-
” for negative
electrode. This switch selects electrode polarity for the
remote (#21) work sensing lead of automatic or semi-
automatic equipment.
THERMAL PROTECTION LIGHT
The amber thermal protection light will be lit if either of
the two protective thermostats have opened. The out-
put power will be disabled but input power will still be
applied to the welder.
115 VAC and 42 VAC AUXILIARY POWER AND
CONTROL CONNECTIONS
14-Pin Connector
The 14-pin connector receptacle (type MS-3102A-2D-
27SX) supplies auxiliary power.
42 VAC is available at receptacle pins I and K.
A 10 amp circuit breaker protects this circuit.
115 VAC is available at receptacle pins A and J. A 10
amp circuit breaker protects this circuit. note that the
42 VAC and 115 VAC circuits are electrically isolated
from each other.
FRONT VIEW OF 14-PIN CONNECTOR
RECEPTACLE
PIN LEAD NO. FUNCTION
A 32 115 VAC
B GnD Chassis Connection
C 2 Trigger Circuit
D 4 Trigger Circuit
E 77 Output Control
F 76 Output Control
G 75 Output Control
H 21 Work Connection
I 41 42 VAC
J 31 115 VAC
K 42 42 VAC
L --- ---
M --- ---
n --- ---
F = 7 6
G = 7 5
H = 2 1
I = 4 1
J = 3 1
K = 4 2
A = 3 2
B = G N D
C = 2
D = 4
E = 7 7
L
N
M