Lincoln Electric COOL ARC 24 Operator'S Manual Download Page 13

English 11 English 

 WARNING 

Do not touch electrically live parts. 
 

 WARNING 

Before the case of machine will be removed, the machine 
had to be turned off and the power lead had to be 
disconnected from mains socket. 
 

 WARNING

 

Mains supply network must be disconnected from the 
machine before each maintenance and service. After 
each repair, perform proper tests to ensure safety. 
 

 WARNING 

Do not touch electrically live parts. 

Before the case of machine will be removed, the machine 
has to be turned off and the power lead has to be 
disconnected from mains socket. 
 

Pump inlet strainer maintenance 

Poor cooler performance can usually be traced to a 
partially or completely blocked pump inlet strainer. This 
is a user-serviceable item and can be cleaned and 
reused, or replaced  
Continued pump operation with a blocked strainer can 
cause: 

  Voiding of cooler service warranty 

  Damage to the pump head’s inlet areas 

  Torch damage from overheating due to insufficient 

coolant flow rate. 

 
A new or properly cleaned pump inlet strainer should 
restore the cooler’s performance. 
It is recommended to clean or replace the pump's inlet 
strainer at least once a year. 
 

Access the strainer 

  Disconnect welder and cooler from power. 

  The strainer access panel is located on the back 

lower left, remove two screws – see Figure 9. 

 

 

Figure 9 

 

  Next remove the large brass bolt. See Figure 10. A 

deep well socket or tongue and groove pliers may be 
used. A small amount of coolant may leak. 

 

 

Figure 10 

 

Summary of Contents for COOL ARC 24

Page 1: ...IM3105 03 2020 REV03 COOL ARC 24 OPERATOR S MANUAL ENGLISH Lincoln Electric Bester Sp z o o ul Jana III Sobieskiego 19A 58 263 Bielawa Poland...

Page 2: ...2 Safety 3 Introduction 5 Unpacking 5 Unpacking the COOL ARC 24 5 Installation on Power Source 5 Installation and Operator Instructions 6 Recommended power source 6 Input Supply Connection 6 Controls...

Page 3: ...4 Recommended coolant FREEZCOOL W000010167 COOL ARC 24 Do not use Pre packaged welding industry coolants These coolants may contain oil based substances which attack the plastic components of the cool...

Page 4: ...ontrolled equipment Safety and control equipment for industrial processes Equipment for calibration and measurement Personal medical devices like pacemakers and hearing aids Check the electromagnetic...

Page 5: ...AGNETIC FIELDS MAY BE DANGEROUS Electric current flowing through any conductor creates electric and magnetic fields EMF EMF fields may interfere with some pacemakers and welders having a pacemaker sha...

Page 6: ...holder work clamp or any other electrically live part to touch a gas cylinder Gas cylinders must be located away from areas where they may be subjected to physical damage or the welding process includ...

Page 7: ...unpacking the unit avoid thrusting sharp objects through the carton liner which may puncture the plastic reservoir Save the manual instruction and service directory supplied with the COOL ARC 24 for...

Page 8: ...f nearby radio controlled machinery which may result in injury or equipment damage Read the section on electromagnetic compatibility in this manual Do not operate in areas with an ambient temperature...

Page 9: ...etected WARNING Incorporated into the cooler is an automatic flow sensor to detect low or no coolant flow A low or no flow condition will cause welding output to automatically stop to protect the torc...

Page 10: ...bleeding Filling the reservoir and water lines WARNING Avoid contact with coolant Wear waterproof gloves and protective eye wear WARNING Before filling the coolant reservoir disconnect cooler s power...

Page 11: ...tightened can cause poor cooling efficiency evaporation loss of coolant and low product life The welding set is ready to work Connecting the Cooling System Hoses The power source has to be turned off...

Page 12: ...ll especially after disconnecting the water lines or changing the accessory being cooled Clean the tank filter PERIODIC MAINTENANCE NOT LESS THAN ONCE A YEAR Perform the routine maintenance and in add...

Page 13: ...traced to a partially or completely blocked pump inlet strainer This is a user serviceable item and can be cleaned and reused or replaced Continued pump operation with a blocked strainer can cause Voi...

Page 14: ...lead or order new lead set Clear blockage in hose Avoid kinking or putting sharp bends in water lines Repair leak Fill reservoir Internal water leak Hose clamp loose on one of internal hoses Internal...

Page 15: ...or any customer s particular purpose with respect to such information or advice As a matter of practical consideration we also cannot assume any responsibility for updating or correcting any such info...

Page 16: ...nge in this printing First read the Part List reading instructions above then refer to the Spare Part manual supplied with the machine that contains a picture descriptive part number cross reference R...

Page 17: ...English 15 English Accessories W000010167 FREEZCOOL coolant W000404213 PRESTOTIG 200 AC DC W000404214 CITOTIG 200 AC DC K14189 1 ASPECT 200...