Lincoln Electric COOL ARC 24 Operator'S Manual Download Page 10

English 8 English 

9.  Fuse Receptacle: A 2A fuse is present to protect the 

motor pump. 

 
10. Removable Strainer. The pump is equipped with a 

150um strainer: an external cover is supplied to 
protect the accessible strainer. See Maintenance 
section for more details. 

 

 WARNING

 

Moving parts can injure. Never place fingers into the 
openings of the Cooler. 
 

 WARNING

 

Avoid placing the cooler near a flux hopper or an area 
where dust build-up is extreme. 
 

Circulation of Coolant in the Cooler 

 

 

Figure 6 

 

 WARNING

 

The ambient air temperature influences the parameters of 
cooling. If the ambient temperature is higher, the cooling 
system will be less effective. 
 

 WARNING

 

Avoid kinking or putting sharp bends in any water lines. 
 

 WARNING

 

Never operate the cooler with case off. 
 

 WARNING

 

Avoid placing the cooler near areas of extreme heat. 
 

Preparation COOL ARC

®

 24 to Work 

  Fill the coolant reservoir. 

 Connect 

COOL ARC

®

 24

 to power source. 

  Turn the power source on. 

Warning

: First use the cooler require the pump is 

primed by coolant. 

  Turn power source off. 

  Connect the water-cooler hoses to the cooler’s inlet 

[5] and outlet [4] socket (Figure 3). 

  Turn the power source on. 

Warning

: The water-cooler hoses can require 

bleeding. 

 

Filling the reservoir and water lines 

 

 WARNING

 

 

Avoid contact with coolant. Wear waterproof 
gloves and protective eye wear. 

 WARNING

 

Before filling the coolant reservoir, disconnect cooler’s 
power lead to the power source. 
 
Warning: The cooler can be filled and used only in the 
horizontal position. 
 
Use only recommended coolant FREEZCOOL - 
W000010167  
 

Do not use

 pre-packaged welding industry coolants. 

These coolants may contain oil-based substances, 
which attack the plastic components of the cooler. Once 
added to the cooler, these substances are impossible to 
purge from the water lines and heat exchanger. 
 

Do not use

 automotive anti-freeze. These coolants will 

damage the pump and block of the heat exchanger, 
affecting cooling performance. 

 WARNING 

The coolant reservoir can be filled maximum 2,27l 
coolant. Minimum 1,51l of coolant has to be poured into 
the reservoir. 
 

 WARNING 

Never operate the cooler with the reservoir empty. 
 

 WARNING 

Do not start the cooler with less than 1,50 liters of coolant. 
Operating without enough coolant can prevent full priming 
of the system and may damage the pump. 
 

Priming Pump (only first use the 
cooler) and Bleeding the Cooling 
System 

 

Figure 7 

 

  Assemble the welding setup. 

  Connect the hose with quick water connector (added 

to the equipment) to the cooler’s inlet and outlet 
socket (Figure 5). 

  Fill the coolant reservoir – minimum 2l. 

  Undo the nut. 

 

Summary of Contents for COOL ARC 24

Page 1: ...IM3105 03 2020 REV03 COOL ARC 24 OPERATOR S MANUAL ENGLISH Lincoln Electric Bester Sp z o o ul Jana III Sobieskiego 19A 58 263 Bielawa Poland...

Page 2: ...2 Safety 3 Introduction 5 Unpacking 5 Unpacking the COOL ARC 24 5 Installation on Power Source 5 Installation and Operator Instructions 6 Recommended power source 6 Input Supply Connection 6 Controls...

Page 3: ...4 Recommended coolant FREEZCOOL W000010167 COOL ARC 24 Do not use Pre packaged welding industry coolants These coolants may contain oil based substances which attack the plastic components of the cool...

Page 4: ...ontrolled equipment Safety and control equipment for industrial processes Equipment for calibration and measurement Personal medical devices like pacemakers and hearing aids Check the electromagnetic...

Page 5: ...AGNETIC FIELDS MAY BE DANGEROUS Electric current flowing through any conductor creates electric and magnetic fields EMF EMF fields may interfere with some pacemakers and welders having a pacemaker sha...

Page 6: ...holder work clamp or any other electrically live part to touch a gas cylinder Gas cylinders must be located away from areas where they may be subjected to physical damage or the welding process includ...

Page 7: ...unpacking the unit avoid thrusting sharp objects through the carton liner which may puncture the plastic reservoir Save the manual instruction and service directory supplied with the COOL ARC 24 for...

Page 8: ...f nearby radio controlled machinery which may result in injury or equipment damage Read the section on electromagnetic compatibility in this manual Do not operate in areas with an ambient temperature...

Page 9: ...etected WARNING Incorporated into the cooler is an automatic flow sensor to detect low or no coolant flow A low or no flow condition will cause welding output to automatically stop to protect the torc...

Page 10: ...bleeding Filling the reservoir and water lines WARNING Avoid contact with coolant Wear waterproof gloves and protective eye wear WARNING Before filling the coolant reservoir disconnect cooler s power...

Page 11: ...tightened can cause poor cooling efficiency evaporation loss of coolant and low product life The welding set is ready to work Connecting the Cooling System Hoses The power source has to be turned off...

Page 12: ...ll especially after disconnecting the water lines or changing the accessory being cooled Clean the tank filter PERIODIC MAINTENANCE NOT LESS THAN ONCE A YEAR Perform the routine maintenance and in add...

Page 13: ...traced to a partially or completely blocked pump inlet strainer This is a user serviceable item and can be cleaned and reused or replaced Continued pump operation with a blocked strainer can cause Voi...

Page 14: ...lead or order new lead set Clear blockage in hose Avoid kinking or putting sharp bends in water lines Repair leak Fill reservoir Internal water leak Hose clamp loose on one of internal hoses Internal...

Page 15: ...or any customer s particular purpose with respect to such information or advice As a matter of practical consideration we also cannot assume any responsibility for updating or correcting any such info...

Page 16: ...nge in this printing First read the Part List reading instructions above then refer to the Spare Part manual supplied with the machine that contains a picture descriptive part number cross reference R...

Page 17: ...English 15 English Accessories W000010167 FREEZCOOL coolant W000404213 PRESTOTIG 200 AC DC W000404214 CITOTIG 200 AC DC K14189 1 ASPECT 200...

Reviews: