5
The following is the connection diagram for a 15 VDC encoder:
ENC +15VDC
ENC PULSE
15 volt Encoder
ENC COM
Fig 2-4
15-volt TTL encoder connection
2.4
Motor Connection
The DMC-HV can be used with a permanent magnet, or shunt field motors with an armature rating of
90 – 100 volt dc. The DMC II-LV can be used with a permanent magnet motors with an armature rating
of 10 – 24 volt dc. The following is the connection diagram for a permanent magnet motor:
ARM-
ARM+
Fig 2-4
Permanent magnetic motor wiring