Power-Up Sequence 

When power is applied to the ARC TRACKER™, the 
status light will flash green for up to 60 seconds. During 
this time the unit is performing a self test. The status 
light will also flash green as a result of a system reset or 
configuration change during operation. When the status 
light becomes steady green the system is ready for use. 
 

Duty Cycle 

The ARC TRACKER™ is rated for 1000 A, 44 V DC, 
100% duty cycle. 
 
Note: The correct number and size of welding 
conductors must be used for proper cooling. See the 
installation section for proper connectivity. 
 

Common Welding Procedures 

The ARC TRACKER™ can be used with any DC 
welding process. 
 

Setup Menu Features 

The Setup Menu gives access to the Setup 
Configuration. Stored in the setup configuration are user 
parameters that generally only need to be set at 
installation. The parameters are grouped as shown in 
the following table. 
 

PARAMETER

 

DEFINITION

 

P.1 

through 

P.99

 Unsecured 

Parameters 

(always adjustable) 

P.101 

through 

P.199

 Diagnostic 

Parameters 

(always read only) 

P.501 

through 

P.599

 Secured 

Parameters 

(only accessible through a 
p.c. application) 

 

Set-Up Features Menu 

(See Figure B.1) 
 
A.  To access the set-up menu, press the 

Right

 and 

Left 

buttons of the 

Main Display

 panel 

simultaneously. 

Note 

that the set-up menu cannot 

be accessed if there is a fault (The status 

LED 

is not 

solid green). 
Change the value of the blinking parameter by 
rotating the 

Center

 knob. 

B.  After changing a parameter it is necessary to press 

the 

Right

 hand button to save the new setting. 

Pressing the 

Left

 button will cancel the change. 

C.  To exit the set-up menu at any time, press the 

Right

 

and 

Left 

buttons of the Main Display panel 

simultaneously. Alternately, 1 minute of inactivity will 
also exit the set-up menu. 

 

User Defined Parameters 

 

Parameter

Definition

P.0 Exit 

Setup 

Menu 

This option is used to exit the setup 
menu. When P.0 is displayed, press 
the Left Button to exit the setup menu. 

P.83

Calibration 

See Calibration Specification section 
for further details. 

P.106 View 

Ethernet 

IP 

Address 

Used for viewing the IP address of 
Ethernet compatible equipment. Press 
the Right Button to read the IP 
Address. Press the Left Button to 
back out and exit this option. The IP 
address cannot be changed using this 
option. 

P.505 Setup 

Menu 

Lock 

Determines if the setup parameters 
can be modified by the operator 
without entering a passcode. 
No = The operator can change any 
set menu parameter without first 
entering the passcode even if the 
passcode is non-zero default). 
Yes = The operator must enter the 
passcode (if the passcode is non-
zero) in order to change any setup 
menu parameters. 
This parameter can only be accessed 
using Power Wave Manager software. 

P.506 Set 

User 

Interface 

Passcode 

Prevents unauthorized changes to the 
equipment. The default passcode is 
zero which allows 
full access. A nonzero passcode will 
prevent unauthorized changes to 
setup parameters (if P.505 = Yes). 
This parameter can only be accessed 
using Power Wave Manager software. 

P.509

UI Master Lockout 

Locks all user interface controls, 
preventing the operator from making 
any changes. This parameter can only 
be accessed using Power Wave 
Manager software. 

Summary of Contents for ARC TRACKER K3019-1

Page 1: ...English English 1 IM3047 06 2017 REV01 ARC TRACKERTM OPERATOR S MANUAL ENGLISH THE LINCOLN ELECTRIC COMPANY 22801 St Clair Ave Cleveland Ohio 44117 1199 USA www lincolnelectric eu...

Page 2: ...ference record in the table below your equipment identification information Model Name Code Serial Number can be found on the machine rating plate Model Name Code Serial number Date Where Purchased EN...

Page 3: ...OO ST STO STOO OR EQUIVALENT EXTRA HARD USAGE CORD NEMA 5 15P INCLUDED 230 0 5A ANY NEMA 250V TYPE 230 0 5A EUROPE 3 CONDUCTOR 1 0 mm2 HAR CEE 7 7 All attachment plugs must comply with the Standard fo...

Page 4: ...K3019 number may also contain prefixes and suffixes Is in conformity with Council Directives and amendments Electromagnetic Compatibility EMC Directive 2014 30 EU Low Voltage Directive 2014 35 EU Stan...

Page 5: ...surement Personal medical devices like pacemakers and hearing aids Check the electromagnetic immunity for equipment operating in or near the work area The operator must be sure that all equipment in t...

Page 6: ...AGNETIC FIELDS MAY BE DANGEROUS Electric current flowing through any conductor creates electric and magnetic fields EMF EMF fields may interfere with some pacemakers and welders having a pacemaker sha...

Page 7: ...itable Location UNIT IS IP23 RATED The ARC TRACKER will operate in harsh environments Even so it is important that simple preventative measures are followed in order to assure long life and reliable o...

Page 8: ...he power source and the ARC TRACKER right side weld terminals when viewed from the rear Connect cable s of sufficient size and length from the ARC TRACKER left weld terminals to the work Be sure the c...

Page 9: ...e ARC TRACKER has been calibrated before being shipped from the factory The Lincoln Electric Company recommends that end users of its welding equipment evaluate the suitability of utilizing this produ...

Page 10: ...press the Right hand button to save the new setting Pressing the Left button will cancel the change C To exit the set up menu at any time press the Right and Left buttons of the Main Display panel sim...

Page 11: ...s If other meters are used the compatibility and accuracy with inverter power sources must be determined by the user Volt meter Keithley 2701 Digital Multimeter Ammeter Keithley 2701 Digital Multimete...

Page 12: ...ter Value 100 Dev As Left ARC TRACKER As Left ARC TRACKER As Found Reference Meter Value 100 Table D 1 Nominal Set Point Reference Meter Value Arc Tracker As Found Deviation As Found Arc Tracker As Le...

Page 13: ...erage arc time and will begin to calculate and display heat input F 6 Press the right push button to begin calibration of the volt meter and ammeter located on the ARC TRACKER under calibration G 7 Tu...

Page 14: ...r any customer s particular purpose with respect to such information or advice As a matter of practical consideration we also cannot assume any respon sibility for updating or correcting any such info...

Page 15: ...et information on approved collection systems from our local representative By applying this European Directive you will protect the environment and human health Spare Parts 12 05 For Spare Parts refe...

Page 16: ...ence only It may not be accurate for all machines covered by this manual The specific diagram for a partiuclar code is pasted inside the machine on one of the enclosure panels If the diagram is ellegi...

Reviews: