English
1
IM3047
06/2017
REV01
ARC TRACKER
TM
OPERATOR’S MANUAL
ENGLISH
THE LINCOLN ELECTRIC COMPANY
22801 St. Clair Ave., Cleveland Ohio 44117-1199 USA
www.lincolnelectric.eu
Page 1: ...English English 1 IM3047 06 2017 REV01 ARC TRACKERTM OPERATOR S MANUAL ENGLISH THE LINCOLN ELECTRIC COMPANY 22801 St Clair Ave Cleveland Ohio 44117 1199 USA www lincolnelectric eu...
Page 2: ...ference record in the table below your equipment identification information Model Name Code Serial Number can be found on the machine rating plate Model Name Code Serial number Date Where Purchased EN...
Page 3: ...OO ST STO STOO OR EQUIVALENT EXTRA HARD USAGE CORD NEMA 5 15P INCLUDED 230 0 5A ANY NEMA 250V TYPE 230 0 5A EUROPE 3 CONDUCTOR 1 0 mm2 HAR CEE 7 7 All attachment plugs must comply with the Standard fo...
Page 4: ...K3019 number may also contain prefixes and suffixes Is in conformity with Council Directives and amendments Electromagnetic Compatibility EMC Directive 2014 30 EU Low Voltage Directive 2014 35 EU Stan...
Page 5: ...surement Personal medical devices like pacemakers and hearing aids Check the electromagnetic immunity for equipment operating in or near the work area The operator must be sure that all equipment in t...
Page 6: ...AGNETIC FIELDS MAY BE DANGEROUS Electric current flowing through any conductor creates electric and magnetic fields EMF EMF fields may interfere with some pacemakers and welders having a pacemaker sha...
Page 7: ...itable Location UNIT IS IP23 RATED The ARC TRACKER will operate in harsh environments Even so it is important that simple preventative measures are followed in order to assure long life and reliable o...
Page 8: ...he power source and the ARC TRACKER right side weld terminals when viewed from the rear Connect cable s of sufficient size and length from the ARC TRACKER left weld terminals to the work Be sure the c...
Page 9: ...e ARC TRACKER has been calibrated before being shipped from the factory The Lincoln Electric Company recommends that end users of its welding equipment evaluate the suitability of utilizing this produ...
Page 10: ...press the Right hand button to save the new setting Pressing the Left button will cancel the change C To exit the set up menu at any time press the Right and Left buttons of the Main Display panel sim...
Page 11: ...s If other meters are used the compatibility and accuracy with inverter power sources must be determined by the user Volt meter Keithley 2701 Digital Multimeter Ammeter Keithley 2701 Digital Multimete...
Page 12: ...ter Value 100 Dev As Left ARC TRACKER As Left ARC TRACKER As Found Reference Meter Value 100 Table D 1 Nominal Set Point Reference Meter Value Arc Tracker As Found Deviation As Found Arc Tracker As Le...
Page 13: ...erage arc time and will begin to calculate and display heat input F 6 Press the right push button to begin calibration of the volt meter and ammeter located on the ARC TRACKER under calibration G 7 Tu...
Page 14: ...r any customer s particular purpose with respect to such information or advice As a matter of practical consideration we also cannot assume any respon sibility for updating or correcting any such info...
Page 15: ...et information on approved collection systems from our local representative By applying this European Directive you will protect the environment and human health Spare Parts 12 05 For Spare Parts refe...
Page 16: ...ence only It may not be accurate for all machines covered by this manual The specific diagram for a partiuclar code is pasted inside the machine on one of the enclosure panels If the diagram is ellegi...