TIG SETUP AND USE
Procedure for TIG welding with a Foot Pedal
TIG welding with a foot pedal requires a Lincoln Electric K1782-16
Ready to Weld TIG Torch, a K4361-1 Foot Pedal and
a bottle of
100% Argon Shielding Gas. The foot pedal permits the
output
current to be adjusted while welding. The foot pedal can be
used
to initiate the welding output and the flow of argon shielding
gas.
The machine will automatically detect when the foot pedal is
connected and set the machine to TIG mode.
Connect the Items to the machine as shown below
FIGURE B.6
The welding arc current will be determined by the position of the
foot pedal and the position of the V/A dial present on the front of
the machine. In order to achieve maximum output, the V/A dial
must be set to the letter “J” position and the foot pedal must be
fully closed. Lower outputs can be achieved by reducing the V/A
dial or by reducing the pressure on the foot pedal. To start the
welding arc, lightly touch the tungsten to the piece that is to be
welded and then press the foot pedal. Slowly pull or rock the
tungsten off the work piece and the welding arc will initiate. After
the foot pedal is released the shielding gas will continue to flow
for 8 seconds. This post flow period is used to prevent contam-
ination to the tungsten while the tungsten is still warm and to
prevent contamination of the weld puddle.
Procedure for TIG welding without a Foot Pedal
FIGURE B.7
The welding output current will be determined by the position of
the V/A dial present on the front of the machine. To start the
welding arc, lightly touch the tungsten to the piece that is to be
welded and keep the tungsten on the work piece for about 1
second to initiate the Argon shielding gas. Slowly pull or rock the
tungsten off the work piece and the welding arc will initiate. After
welding is complete the shielding gas will continue to flow for 8
seconds. This post flow period is used to prevent contamination to
the tungsten while the tungsten is still warm and to prevent conta-
mination of the weld puddle.
K1782-17 Ready to
Weld TIG Torch
100% Argon
Shielding Gas.
K4361-1 Foot Pedal
K1782-17 Ready to
Weld TIG Torch
100% Argon
Shielding Gas.
MULTIPROCESS WIRE FEEDER WELDER
Summary of Contents for 180i MP
Page 23: ...F 4 DIAGRAMS MULTIPROCESS WIRE FEEDER WELDER 8 76 8 87 18 06 13 60 ...
Page 24: ...This page intentionally left blank ...
Page 25: ...This page intentionally left blank ...
Page 50: ...SOLDADORA ALIMENTADORA DE ALAMBRE MULTIPROCESOS DIAGRAMAS F 3 ...
Page 51: ...SOLDADORA ALIMENTADORA DE ALAMBRE MULTIPROCESOS DIAGRAMAS F 4 8 76 8 87 13 60 S20601 12 18 06 ...
Page 52: ......
Page 53: ......
Page 78: ...DÉVIDOIR DU SOUDEUR MULTIPROCESSUS SCHÉMAS F 3 ...
Page 79: ...DÉVIDOIR DU SOUDEUR MULTIPROCESSUS SCHÉMAS F 4 ...
Page 80: ......
Page 81: ......
Page 83: ......