E-3
TROUBLESHOOTING
FRONTIER
®
400X
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Lincoln Authorized Service Facility for technical troubleshooting assistance before you proceed.
WWW.LINCOLNELECTRIC.COM/LOCATOR
PROBLEMS
(SYMPTOMS)
POSSIBLE
CAUSE
RECOMMENDED
COURSE OF ACTION
Battery does not stay charged.
Engine will not idle down to low
speed.
Engine will not go to high idle when
attempting to weld.
Engine will not go to high idle when
using auxiliary power.
1. Faulty battery.
2. Faulty engine alternator.
3. Loose or broken lead in charging
circuit.
4. Loose fan belt may need tighten-
ing.
1. Idler switch in HIGH idle position,
make sure switch is set to AUTO.
2. Faulty Idler Switch.
3. Faulty Idle Relay.
1. Poor work lead connection to
work. Poor lead connections to
machine.
2. Welding output is OFF. (No open
circuit voltage at output studs)
3. Faulty Idle Relay.
1. Broken wire in auxiliary current
sensor wiring.
2. Auxiliary power load is less than
100W.
3. Faulty Auxiliary Sense Toroid.
If all recommended possible areas
of misadjustment have been
checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.