B-21
OPERATION
FRONTIER
®
400X
SIMULTANEOUS WELDING AND AUXILIARY POWER
LOADS
The auxiliary power capacity previously stated is maintained
without any welding load. If a welding load is present, the
available auxiliary power will decrease.
The permissible currents shown assume that current is being
drawn from either the 120 VAC or 240 VAC supply (not both at the
same time).
TABLE B.4 FRONTIER
®
400X EXTENSION
CORD LENGTH RECOMMENDATIONS
Current
(Amps)
15
15
20
20
25
30
38
50
Voltage
(Volts)
120
240
120
240
240
240
240
240
Load
(Watts)
1800
3600
2400
4800
6000
7200
9000
12000
30
60
(9)
(18)
40
75
30
60
(12)
(23)
(9)
(18)
75
150
50
100
90
75
(23)
(46)
(15)
(30)
(27)
(23)
125
225
88
175
150
120
100
(38)
(69)
(27)
(53)
(46)
(37)
(30)
175
350
138
275
225
175
150
125
(53)
(107)
(42)
(84)
(69)
(53)
(46)
(38)
300
600
225
450
250
300
250
200
(91)
(183)
(69)
(137)
(76)
(91)
(76)
(61)
Maximum Allowable Cord Length in ft. (m) for Conductor Size
Conductor size is based on maximum 2.0% voltage drop.
14 AWG
12 AWG
10 AWG
8 AWG
6 AWG
4 AWG
Weld
Amps
0
100
200
250
300
400
1 PHASE
WATTS
AMPS
10,000
42
8300
35
5300
22
3500
15
400
2
0
0
3 PHASE
WATTS
AMPS
11,000
27
8500
20
5700
14
3500
8
800
2
0
0
BOTH 1 & 3 PHASE
WATTS
AMPS
10,000
-
8300
-
5300
-
3500
-
400
-
0
0
FRONTIER
®
400X Simultaneous Welding and Power Loads
PLUS
OR
OR
TABLE B.3