background image

IS392  ECN4127 

Page 5 

PRODUCT SPECIFICATION 

FEATURES 

TECHNICAL SPECIFICATION 

 
 
 
 

 
Refrigerated Showcase – SCR785, SCR1085 

 
 
 
 

 

 

 
Fan-assisted refrigeration 
Toughened single glazed glass 
Electronic control 
Temperature alarm 

Sliding rear doors 
Independently switchable light 
Fixed shelf position  
230 Volt, 50 Hz, single phase 

Removable side glass 

 

 

     & 230 Volt, 50 Hz, single phase 

 

 
 
 
 
 
 

 
Model 

SCR785 

SCR1085 

Max. Operating 
Temperature 

O

25 

25 

Volume (gross) 

litres 

140 

190 

Internal Dimensions 

mm 

746x470x620  1046x470x620 

Width 

mm 

785 

1085 

Depth 

mm 

750 

750 

Height 

mm 

665 

665 

Power Rating 

Watt 

360 

440 

Weight (net) 

kg 

81.5 

101.0 

Refrigerant 

R452a 

 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for SCR1085

Page 1: ...IS392 ECN3621 User and Installation Instructions Seal Refrigerated Showcases SCR785 and SCR1085 ...

Page 2: ...fety and operating instructions carefully before using this product Please pay particular attention to all sections of this User Guide that carry warning symbols and notices WARNING This is a Warning symbol This symbol is used throughout the user guide whenever there is a risk of personal injury Ensure that these warnings are read and understood at all times CAUTION This is a Caution symbol This s...

Page 3: ...7 Connecting to the electricity supply 7 Operating instructions 8 Temperature controller and fault finding 9 Cleaning and maintenance 10 Cleaning the condenser 10 Replacing the light tube 10 Service information 11 Conditions of guarantee 11 USE OF THE REFRIGERATED SHOWCASES The Refrigerated Showcases are intended to be used on counter tops to display pre chilled food product ...

Page 4: ... Be aware of the risks when lifting or moving it Always lift the showcase using the base do not lift with any other part Do not pull the unit across your work surface as it may make a mark The cabinet relies on the circulation of cold air which must pass through and around the shelf Ensure circulation is not obstructed by food product blocking the internal vents GENERAL Do not try to modify this p...

Page 5: ...rm Sliding rear doors Independently switchable light Fixed shelf position 230 Volt 50 Hz single phase Removable side glass 230 Volt 50 Hz single phase Model SCR785 SCR1085 Max Operating Temperature O C 25 25 Volume gross litres 140 190 Internal Dimensions mm 746x470x620 1046x470x620 Width mm 785 1085 Depth mm 750 750 Height mm 665 665 Power Rating Watt 360 440 Weight net kg 81 5 101 0 Refrigerant ...

Page 6: ...BU173 BU172 Compressor CR08 CR07 Evaporator Fan S R181 S R181 Condenser Fan FA62 FA62 Shelf SH102 SH103 Temperature Controller EC16 EC16 Diffuser DI29 DI30 Starter GL68 GL68 Shelf Pin SP05 SP05 Component Model 60Hz SCR785 SCR1085 Light Tube BU173 BU172 Compressor CR12 CR11 Evaporator Fan S R181 S R181 Condenser Fan FA62 FA62 Shelf SH102 SH103 Temperature Controller EC16 EC16 Diffuser DI29 DI30 Sta...

Page 7: ...tion on the outer surfaces of the cabinet and must be avoided Ambient temperature range minimum 18o C maximum 25o C Maximum relative humidity 60 For safety regulations the plug must always be accessible Leave the product to stand for three hours before connecting to the power supply and switching on CONNECTING TO THE ELECTRICITY SUPPLY Ensure that the voltage of your electricity supply corresponds...

Page 8: ...side at 3 to 5o C The temperature displayed is the air inside the cabinet and not the temperature of the food product The displayed temperature will fluctuate as the refrigeration system cycles At 4 hour intervals the system will automatically defrost The display will indicate that it is in defrost mode refer to page 9 LOADING Load the cabinet with pre refrigerated products only taking care to all...

Page 9: ...abinet temperature of the unit is higher than the factory setting then possible causes are Doors left open Food product not pre chilled Excessive ambient temperature above 32 o C Condenser obstructed check clean Evaporator blocked by ice If this is the case manually defrost by pressing the buttons marked for 2 seconds If necessary also switch off the unit for 3 4 hours 4 If cabinet temperature of ...

Page 10: ...sary to clean the condenser or replace a light tube CLEANING THE CONDENSER Disconnect the unit from the electricity supply The condenser is located behind the rear panel remove the screws holding this panel in place and remove the panel to expose the condenser Use a vacuum cleaner to remove any debris from the face of the condenser Replace the panel and refit all of the screws REPLACING THE LIGHT ...

Page 11: ...roblem Product code type number and serial number of unit both on serial plate Code number of spare part see spare parts list if known Lincat reserve the right to carry out any work under warranty during normal working hours i e Monday to Friday 8 30 a m 5 00 p m This unit carries a comprehensive UK twelve month warranty The guarantee is in addition to and does not diminish your statutory or legal...

Page 12: ...IS392 ECN4127 Page 12 This page is intentionally blank ...