IS707 ECN 4277
9
Pan detection function
This prevents the coils being turned on without a pan being present, and also turns
off the coil as soon as a pan is removed. If the pan is of the wrong material for
induction equipme
nt, the ‘no pan present’ symbol is displayed. After use, switch off
the hob via the control and do not rely on the pan detector.
Residual heat display
When the temperature of the hob top exceeds 60
o
C after removal of a pan, the ‘H’
symbol displays, indicating a hot surface. (Refer also to the error codes section).
Whilst the residual heat display is showing, leaving the appliance connected to the
power supply allows the cooling fans to continue to operate. When the ‘H’ symbol is
extinguished, switch off the power supply.
Error codes
There are numerous error codes identifying issues within the induction system. These
are primarily of use when reporting a fault to
Lincat’s Service Department; however
some errors can be cleared by turning the control
to the ‘Off’ position, unplugging the
appliance and then switching back on again.
A reduction in performance during cooking may be attributed to a blocked or restricted
air filter, a confined location with insufficient airflow or a failed cooling fan.
Error codes are shown on the display
This list shows the standard error codes. As standard general TC (thermocouple)
errors are
“Er xx“and cooking element specific errors E/x are displayed.
Error code
Description
Possible cause of error
Remedy
Er 03 and
continuous
tone or
continuous sensor activation; TC
turn off after 10 sec
Water or cookware on the
glass over the touch
control sensors
Clean the control surface,
remove objects on the
sensors
Er 20
Flash memory
– TC error
µC- defective
Replace TC
Er 22
Button evaluation defective, UI
shuts off after 3.5-7.5 sec
Short or open circuit in the
area of the button sensor
Replace TC
Er 31
Incorrect configuration data or
deviation between generator and
TC
New configuration of the
induction generator
required
New configuration (Service
menu)
Er 36
NTC value defective on TC; UI
turns off
Short or open circuit of
NTC
Replace TC
Er 47
Communication error between
TC and induction
No or erroneous LIN
communication! (Slave
does not answer to
request of master)
Connection cable not
correctly plugged in or
defective.
U 400
Continuous tone
Power supply on inlet to high
Incorrect connection of the
cooktop
Correct power supply
connection
E / 2
Excess temperature of the
induction element
Overload of cooktop or
empty boiled cookware
Let system cool down.
E / A
Error on the power board
Component failure
Replace power board