IS 469 ECN 3607
Page 5 of 15
Water supply and connection
Install in accordance with BS EN 1717 and the National Water Regulations in Use.
Connection is at the rear of the appliance via a 15mm compression fitting with
check valve (Fig 2).
When making the connection to the appliance, fit an isolating cock into the supply
line, close to the appliance, for emergency shutdown or servicing purposes.
Connect the overflow pipe at the rear of the appliance to a drain.
Fig 2
Electrical supply and connection
Means of isolation with at least 3mm contact separation in all poles must be
incorporated into the fixed wiring of this appliance.
The fixed wiring insulation must be protected by insulated sleeving having a
temperature rating of at least 60 Deg C.
Supply cords shall be oil resistant, sheathed flexible cable not lighter than ordinary
polychloroprene or equivalent elastomer sheathed cord (code 60245 IEC 57).
A Overflow pipe
B Cable inlet
C Water inlet 15mm
compression